The B 604 automated system is an electronic barrier designed for
vehicle accesses
The automated system mainly consists of three parts:
A motor body which integrates the non-reversing low voltage
motor, the control board, the flashing light, the balancing spring
and the release system.
The rod of which several types are available according to instal-
lation requirements.
The securing support, available for on-wall or on-column instal-
lation.
The built-in control unit was positioned to facilitate all the wiring,
programming and adjustment operations.
A handy manual release, protected by a personalised key, makes it
possible to move the rod manually in the event of a power cut.
Before you begin to install the barrier, read all the instructions
carefully. Incorrect installation or incorrect use of the au-
tomated system could be a source of danger to people.
The automated system was designed and built for vehicle
access only - do not use for any other purpose.
Anything not expressly specified in these instructions is not
permitted.

1. DESCRIPTION OF COMPONENTS

Pos.
Pos.
Motor body
Motor body
Control unit
Control unit
Release device
Release device
Rod carrying pocket
Rod carrying pocket
Covering housing
Covering housing
Flashing light
Flashing light
Wall mounting kit (not supplied)
Wall mounting kit (not supplied)
Column kit (not supplied)
Column kit (not supplied)
B 604 AUTOMATED SYSTEM
Description
Description
Fig. 1
Fig. 1

2. TECHNICAL SPECIFICATIONS

MODEL
Power supply
Motor power supply
Absorbed power
Absorbed current
Max. torque.
Opening time
Max beam length
Max consecutive cycles
Operating ambient temperature
Motor body weight
Protection class
Dimensions
The indicated opening time refers to a correct installation
(1)
without any slow downs
3. DIMENSIONS
4. ELECTRIC PREPARATIONS (standard system)
Fig.4 shows an installation with column support. The electrical ca-
bles to be prepared are the same as those for on-wall installation;
for the position of the cables, refer to paragraph 4.3.
To lay cables, use adequate rigid or flexible tubes.
8
B 604
230/115 Vac 50/60Hz
24 Vdc
80 W
0.35 A
130 Nm
3 sec
(1)
4 m
100
-20 ÷ +55°C
20 Kg
IP 44
See fig. 2
Fig. 2
Fig. 2
Fig. 3
Fig. 3