INSTALLATION
Switch the device on by pressing the ON button once.
Press the ON button once again, the air flow is at level 1 (~170L/min).
Press the ON button once again, the air flow is at level 2 (~200L/min).
Press the ON button once again, the air flow is at level 3 (~230L/min).
Press the ON button once again, the air flow reverts to level 1 (~170L/min).
The filtration system goes automatically in sleep mode after 30 minutes of inactivity.

TROUBLESHOOTING

MEANING
Fault code «E01» +
blinks
Fault code«E02» +
blinks
blinks +
blinks + alarm
sounds
blinks +
blinks + alarm
sounds
blinks + alarm sounds
No air flow, no alarm
Battery autonomy is too low
Unusual smell in the helmet
Insufficient air flow
MAINTENANCE
The filtration unit and the helmet must be regularly cleaned in order to remain in a good working order.
No liquid must go inside the filtration unit or on the main filter Let the cleaned parts dry out before putting them back. Never use
solvents or abrasive cleaners. The filtration unit must not be dried with hot air or with a heater.
The filter must be replaced if it blocked or broken. The breathing hose must be replaced if fractured.
The battery must be charged as soon as the «low battery» indicator switches on. To keep the battery in good working order, it is
strongly recommended not to exceed 10 months of storage without use.
Use a soft cloth to clean external surfaces. Do not use water!
The filter must be replaced at the same time as the pre-filter.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported.
18
GYSMATIC 9/13 XL • 5/13 XXL
CAUSES
Motor is obstructed or damaged.
- Obstructed motor
- Circuit overheating
Low battery
Obstructed filter or hose
Thermal protection
- No power
- Loose electrical contact (battery)
- The battery is not charged at a 100%
- Obstructed filter
- Worn out battery
- Broken filter
- Broken hose
- Internal helmet screen is broken
- Pierced or broken hose
- Semi obstructed filter
SOLUTIONS
Visually check the motor by removing the filter panel and restart the
filtration system. If the error persists, the system is damaged, do
not use it.
Charge the battery
Remove the obstruction, change / clean the flexible hose
Wait for the indicator to turn off before resuming welding opera-
tions.
- Charge the battery
- Remove and put the battery back.
- Charge the battery
- Remove the battery, change the filter
- Replace the battery
Leave the working area :
- Replace the filter
- Replace the hose
- Replace the internal screen
- Check that the hose is connected to the respiratory system and
the helmet.
- Change the respiratory hose.
- Remove the obstruction or replace the filter.