DETERMINE HOOD, DUCTWORK AND WIRING LOCATIONS
Draw the line to ceiling height.
hood to the cooking surface, 30" min. to 36" max.
NOTE: If you are installing the hood with duct covers,
be sure to read "Using Duct Cover Accessories" page
7. Exact installation height may be determined by use
of one or more duct covers.
indicating the bottom of the hood.
measure 15-3/8" up and draw another line for the
location of the wood support. See illustration.
FOR VERTICAL (Straight Up) DUCTING:
the hood to ceiling or soffit.
forward on the ceiling or soffit.
or soffit by measuring 6" from the wall.
House Wiring Location:
on the right side.
8-3/8"
Electrical
Area
large area for the house wiring to exit the wall and
be routed to the rear knockout and junction box.
strain relief.
14
Installation Instructions
18-13/16" for 48" Models
12-13/16" for 36" Models
9-13/16" for 30" Models
Top of Hood
Wood
Support
15-3/8"
Bottom of Hood
FOR DUCTING THROUGH REAR WALL:
of the hood. At the centerline, mark location for a
10-1/2" diameter hole.
NOTE: Minimun ceiling height for REAR WALL
EXHAUST with duct covers is 8'4" when installing at
30" above countertop using 10" elbow
Alternate Knockout Locations
If the installation requires, the junction box can
be relocated from the back to the top of the hood.
Remove 3 screws, align box to top knockout and
secure with original screws.
strain relief.
9-7/8"
18"
18-1/16" for 48" Models
12-1/16" for 36" Models
9-1/16" for 30" Models
6-1/2"
49-80819