Off: Signals AM and TF on the AM relay (factory default).
SW 5: Setting LEDs
On: Enables both LEDs on the detector at all times (factory
default).
Off: Puts both LEDs under the control of the Walk Test and
Day/Night input. This activates the memory feature of the
detector.
AM calibration
During start-up the AM circuitry calibrates itself to its
environment. It is important to make sure that there are no
changes made to the environment within 1 m distance of the
detector within 60 s after powering up, otherwise the detector
may be vulnerable to false AM alarms and these alarms may
be impossible to reset.

LED indication

PIR
Red LED
Alarm relay
Start up
Closed
Low voltage
Open (Alarm)
PIR intruder
Open (Alarm)
alarm
PIR/AM
Red
Yellow
LED
LED
Start up
Low voltage
PIR intruder
alarm
Latched PIR
(Memory)
AM alarm
After AM
reset
Technical
fault
Continuously on
Normal blinking (1 Hz)
Fast blinking (4 Hz)
* Depends on the setting of the DIP switch SW4.
Specifications
Detector
Signal processing
Range
Optical
Memory
Input power
For UL/cUL installations
Peak-to-peak ripple
Detector start-up time
P/N 146279999-2 (ML) • REV H • ISS 11MAR19
To reset
Automatically after 25 s
Apply correct voltage
Automatically after 3 s
To reset
Alarm
AM
relay
relay
Closed
Closed
Automatically
after 60 s
Open
Open
Apply correct
(Alarm)
(Alarm)
voltage
Open
Automatically
(Alarm)
after 3 s
Switch to Night
mode
Open*
Open
See DIP
(Alarm)
(Alarm)
switch 3
Switch to Night
mode
Open
Do a successful
(Alarm)
walk test
PIR
PIR with anti-
masking
V2E
20m
11 high-density mirror curtains
Yes
9 to 15 VDC (12 V nominal)
10 to 15 VDC (12 V nominal)
2 V (at 12 VDC)
25 s
60 s
Detector
Normal current
For UL/cUL installations
Current in alarm
Maximum current
(LED on)
Mounting height
Target speed range
Alarm (NC) / Tamper relay
characteristic
Pry-off tamper (not
evaluated by UL/cUL)
AM relay characteristic
PIR Alarm time
Operating temperature
For UL/cUL installations
Dimensions (H x W x D)
Relative humidity
Weight
IP/IK rating

Regulatory information

Manufacturer
Placed on the market by:
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
THESE PRODUCTS ARE INTENDED FOR
and disclaimers
SALE TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. UTC FIRE & SECURITY
CANNOT PROVIDE ANY ASSURANCE THAT
ANY PERSON OR ENTITY BUYING ITS
PRODUCTS, INCLUDING ANY "AUTHORIZED
DEALER" OR "AUTHORIZED RESELLER", IS
PROPERLY TRAINED OR EXPERIENCED TO
CORRECTLY INSTALL FIRE AND SECURITY
RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/ or scan the QR code.
Certification
PIR
PIR with anti-
masking
6.5 mA
10 mA
0.078 W
1.2 mA
3.8 mA
11 mA
24 mA
1.8 to 3.0 m
2.0 to 3.0 m
(5.9 ft.to 9.8 ft.)
(6.6 ft.to 9.8 ft.)
30 cm/s to 3 m/s
20 cm/s to 3 m/s
(1 ft./s to 10 ft./s)
(0.65 ft./s to 10 ft./s)
80 mA, 30 VDC,
80 mA, 30 VDC
resistive
Optional
Onboard (yes)
80 mA
at 30 VDC max.
3 s
−10 to +55°C (14 to 130°F)
0 to +49°C ( 32 to 120°F )
125 × 55 ×
125 × 65 × 60 mm
60 mm (4.92
(4.92
x 2.16 x 2.36 in.)
x 2.6 x 2.36 in.)
95% max. noncondensing
(UL/cUL Installations)
150 g
IP30 IK02