A(mm)
B(mm)
760
50 mini
Before you install the hob, make sure that
• the work surface is square and level, and no structural members interfere with space requirements
• the work surface is made of a heat-resistant material
• if the hob is installed above an oven, the oven has a built-in cooling fan
• the installation will comply with all clearance requirements and applicable standards and regulations
• a suitable isolating switch providing full disconnection from the mains power supply is incorporated in the
permanent wiring, mounted and positioned to comply with the local wiring rules and regulations.
• The isolating switch must be of an approved type and provide a 3 mm air gap contact separation in all
poles (or in all active [phase] conductors if the local wiring rules allow for this variation of the requirements)
• the isolating switch will be easily accessible to the customer with the hob installed
• you consult local building authorities and by-laws if in doubt regarding installation
• you use heat-resistant and easy-to-clean finishes (such as ceramic tiles) for the wall surfaces surrounding
the hob.
C(mm)
D
20 mini
Air intake
44
INDUCTION COOKER
TPI060210MD
E
Air exit 5mm

Publicidad