Glass Doors; Maintenance And Cleaning - Qualified Operator - Arneg Osaka 2 90 H216 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Osaka 2
English
Unhook the light fixture from the shelf.
Remove the methacrylate guard (1), slide out the bulb (2) from the housing, and
replace it with the new one.
Reinsert the light, making sure that the contacts are correctly placed in the
appropriate openings.
Reattach the methacrylate guard.
Hook the light fixture back onto the shelf.
Restore the electricity supply.

19.Glass doors

The unit has front wing doors in low heat-dispersion glass.
Sliding doors are available on request.
The doors in low heat-dispersion glass allow for a noticeable reduction in refrigeration
energy, ensuring improved temperature level of foodstuffs and guaranteeing conserva-
tion quality.
(Rif. 26) The doors are provided with automatic closure and close automatically
starting from an angle of approx. 70°.
Beyond 70° the doors will be in stand-by -- essentially they remain in place in
order to allow for loading or cleaning operations. To unblock them and close the
doors, simply accompany them to the closed position.
In case of difficulty in opening or closing, DO NOT force them but try to find
the cause of the malfunction.
Avoid actions not envisaged for the closing and movement system.

20.Maintenance and cleaning - qualified operator -

BEFORE CARRYING OUT ANY MAINTENANCE WORK OR
CLEANING, FIRST DISCONNECT THE UNIT FROM THE VOLTAGE
SUPPLY BY MEANS OF THE GENERAL SWITCH. ALWAYS WEAR
PROTECTIVE GLOVES FOR CLEANING.
Food products can deteriorate due to microbes and bacteria. Respecting hygiene
norms is essential in order to guarantee protection of consumer health, as well as
respecting the chain of refrigeration, for which the sales point is the last controllable
ring.
Cleaning operations must include:
1 - WASHING (removing grease, removal of about 97% of the dirt)
2 - DISINFECTING (using appropriate detergents on the surfaces to remove any
pathogenic micro-organisms that might remain after washing).
3 - RINSING
4 - DRYING
Cleaning the refrigeration units is carried out as follows:
34