TROUBLESHOOTING

Description
• The appliance stops working while it is
switched on and the all four suction power
indicator lights start to blink together.
• The appliance will not start.
• Obvious reduction in suction power.
• Water leaks when you use the appliance to
clean up liquids.
Possible causes and solutions
• Wait for about 30 sec. before using the aps t
pliance again. This allows the machine to
reset while you check for one of the following
causes:
• The water has become very dirty and dense.
Empty the water from the container and refill
it with clean water.
• The water level is above "MAX". Reduce the
water level.
• The selected suction power level is too high
for the task in hand. Reduce the suction
power.
• The air flow is blocked. Remove the blocks t
age.
• The power cord is not correctly connected to
the socket.
• The filters need to be replaced.
• The openings, the telescopic tube or the sucs t
tion hose are blocked by dirt. Bending the
hose during operation will remove the dirt or
dust blocking the hose and therefore, any obs t
struction.
• The water filter is clogged. Remove and diss t
assemble the filter before cleaning all of its
parts.