Connect The Wiring - Broan BUEZ3 Serie Manual Del Usuario

Campana de extractora
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

FRAMELESS
CABINET
3 X
7/64"
 A lign the corresponding bracket to the cabinet side, while placing
rear end of bracket against the wall. Draw a line on the outer edge
of the bracket (as shown).
 S lide the bracket towards the center of cabinet and align the outside
edge of the bracket with the marked line, keeping the rear end edge
leaning on the wall.
Use a pencil to mark 3 holes.
 R emove the bracket. Using a 7/64" drill bit, drill 3 holes where marked.
 A ssemble the bracket to the cabinet bottom using a Phillips
screwdriver and 3 provided countersunk wood screws. Repeat for
the other cabinet side.
The following procedure applies to both framed or frameless
cabinet installations.
HORIZONTAL EXHAUST INSTALLATION ONLY
1. Pull house power cable out.
2. Temporarily hang the hood on the brackets using its 2 recessed
REAR HOLES (A and B). While holding the hood, run the house
power cable into the hood through the strain relief previously installed.
3. Unhook the rear holes from the brackets and hang the hood using
its 2 recessed FRONT HOLES. While holding the hood, attach the
power cable to the hood using the strain relief.
A
VERTICAL EXHAUST INSTALLATION ONLY
1. Pull house power cable out.
2. Hang the hood on the brackets using the 2 recessed FRONT
HOLES. While holding the hood, run the house power cable into
the hood through the strain relief previously installed. Attach power
cable to the hood.
B
For framed cabinet, secure the hood to the EZ1 brackets using
4 no. 8-18 x 1/2" metal screws (included). Insert 2 screws per side,
in the slots.
For frameless cabinet, secure the hood to the cabinet using
4 no. 8 x 5/8" round head wood screws (included). Insert 2 screws per
side, in the slots.
FRAMED
CABINET
STANDARD INSTALLATION
1. Hold hood up against cabinet bottom and trace keyhole slots onto
cabinet bottom or filler strips.
2. Screw the four supplied screws for mounting the hood into the exact
center of the narrow end of the keyhole slots marked underneath the
cabinet. Allow 3/8" of the screws to project, so the hood can be fitted
into place.
3. Run electric wiring through hole drilled in wall or cabinet. Split wiring
for 6" and run the house power cable into the hood through the strain
relief previously installed. Attach power cable to the hood.
4. Position hood so that:
a.) Large part of keyhole slots fit over hood mounting screws.
b.) Damper/duct connector slides into ductwork (3-1/4" x 10" vented
hoods only)
5. Adjust hood so that hood front is flush with cabinet frame.
6. Tighten hood mounting screws firmly.

CONNECT THE WIRING

WARNING: TURN OFF THE PROPER CIRCUIT AT THE SERVICE
ENTRANCE BEFORE WIRING THIS RANGE HOOD. ALL ELECTRICAL
CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL
CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU
ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL
WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.
1. Make electrical connection using wire nuts to connect WHITE wire
to WHITE, BLACK wire to BLACK, and GREEN or bare wire to GREEN
ground screw provided.
2. Replace wiring box cover and screw, taking care not to pinch wires.
4
FRAMELESS
CABINET
M
ETAL
S
CREWS
KEYHOLE SLOT OUTLINE
FILLER
STRIPS
W
OOD
S
CREWS

Publicidad

Tabla de contenido
loading

Tabla de contenido