Type
CP system design
Number of CP strings
Cable length per CP string
Number of CP modules per CP
string
Number of inputs / outputs per
CP string
Update time:
all CP strings allocated
exclusively with modules with
advanced functionality
mixed string allocation
Supports CP system's advanced
functionality
Voltage drop of CPX system or
additional supply up to CP
connection...
From operating voltage supply for
electronics/sensors (V
From load voltage supply for
valves (V
)
val
Short−circuit protection for CPX−CP
interface
For CP sensor supply
For CP load voltage supply
Behaviour after short circuit
Error correction
18
CPX−CP−4−FB
4
max. 10 m
max. 4
32 I / 32 O
max. 2 ms
max. 4 ms
Yes
max. 1 V
)
el/sen
max. 1 V
> 1.8 A per string, slow−blowing
> 1.8 A per string, slow−blowing
Power remains switched off
Power Off/On necessary (power
does not return automatically)