Descargar Imprimir esta página

GYS M1 auto Manual De Usario página 16

Ocultar thumbs Ver también para M1 GYS auto:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
«sYnerGic» Mode (FiG 5)
This function will set the wire speed automatically.
For this:
Position the wire speed potentiometer (2) in the middle of the« Optimal synergic » zone.
-Select:
-The wire type (5)
-The wire diameter (5) The power mode (7 position switch), to select the right position in accordance with the thic-
kness of the part to weld, please refer to the table (fig 6)
From this combination, they determines the optimal wire speed and the device is ready to weld. It is also possible
to adjust the wire speed if necessary by adjusting potentiometer (2) + or – manually. A memory of the last welding
configuration is done (wire diameter, wire type, mode).
GAS choice (only for steel welding) :
In synergic mode, the trimig 205-4S determines the welding settings in accordance with the gas used. By
default, in steel welding the machine is set in « Argon + CO2 ».
To change the gas and set the machine in C02 mode or come back in Argon + CO2 mode, process as
explained:
1-Press « Type » for 5 seconds until the keyboard switches off the release.
2-Within 5 seconds, choose the required setting with the key « choose mode ».
Normal (2T) => Argon + CO2 (default setting)
Delay => CO2 100%
3-The confirmation is done either by the « Type » key, or by waiting for 5 seconds.
4-Once confirmed, the machine reverts to the normal functioning mode but the modification is registered
even when the machines is switched off.
spoT Mode (FiG 5)
This function allows spot welding. To adjust the length of each spot, use the potentiometer (3).
delaY Mode (FiG 5)
Allows intermittent welding, the delay can be adjusted through the potentiometer (3).
This function allows welding very thin steel or aluminium metal sheet, limiting the risk of piercing and distortion
(especially for aluminium welding).
M1 - T1 - T2 eT T3 GYs auTo
en
16

Publicidad

loading

Este manual también es adecuado para:

T1 gys autoT1 gys auto dvT2 gys autoT3 gys auto dv