BFT SIRIO C BA 230 INV Instrucciones De Instalación página 17

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
x 2
follow the
hALT
user guide
add. start
hidden butt
Add. 2ch
hidden butt
erase 64
language
autoset
Control unit
software version
stat
vers
OK
bft . . .
+/-
No total
- +
manoeuvres(in hundreds)
0000
n. cycles
OK
+/-
- +
No radio control
devices memorised
n. remotes
OK
00
+/-
- +
List of last 30 errors
01.33
err
OK
02.01
........
30.15
+/-
0---
password
ACCESS MENUS Fig. 1
See PARAMETERS MENU
See LOGIC MENU
release
desired button
release
desired button
See RADIO MENU
Diagnostics
code
START E external start input activated
STRE
START I internal start input activated
STRI
OPEN input activated
OPEN
CLOSE input activated
CLS
PED pedestrian input activated
PED
TIMER input activated
TIME
STOP input activated
STOP
PHOT photocell input activated
PHOT
PHOT OP opening photocell input activated
PHOP
PHOT CL closing photocell input activated
PHCL
BAR safety edge input activated
BAR
BAR safety edge input activated on slave motor
BAR 2
(opposite leaves connection)
SWC motor closing limit switch input activated
SWC
SWO motor opening limit switch input activated
SWO
The board is standing by to perform a complete opening-
closing cycle uninterrupted by intermediate stops in
SET
order to acquire the torque required for movement.
WARNING! Obstacle detection not active
Photocell test failed
ER01
Safety edge test failed
ER02
Opening photocell test failed
ER03
Closing photocell test failed
ER04
Safety edge test on slave motor failed (opposite leaves
ER05
connection)
8k2 safety edge test failed
er06
Board hardware test error
ER1x
*
Encoder error
ER2x
*
*
Reverse due to obstacle - Amperostop
ER3x
*
Communication error with remote devices
ER5x
*
Internal system supervision control error.
ER7x
*
Inverter alarm
ErF3/ F4/F5
ErF1 / F2
limit switch error
*X= 0, 1, .., 9, A, B, C, D, E, F
10--
150-
35. 4 0
DESCRIPTION
1520
prg
Scroll up
Scroll down
Con rm/Switch on display
Exit Menù
Obstacle threshold
Instantaneous force motor
NOTES
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Check photocell connection and/or logic settings
Check safety edge connection and/or logic settings
Check photocell connection and/or param-
eter/logic setting
Check photocell connection and/or param-
eter/logic setting
Check safety edge connection and/or param-
eter/logic settings
Check safety edge connection and/or param-
eter/logic settings
-
C h e c k
c o n n e c t i o n s
t o
m o t o r
- Hardware problems with board (contact
technical assistance)
- Motor power or encoder signal cables in-
verted/disconnected.
- Actuator movement is too slow or stopped
with respect to programmed operation.
Check for obstacles in path
Check connection with serial-connected
accessory devices and/or expansion boards
Try switching the board off and back on again
If the problem persists, contact the technical
assistance department.
Check the inverter's connections.
Check the inverter's display for any error
messages
check limit switch connections
 