• Function setting
1. Reset to Default configuration.
The original room number for all keys as below:
1303
1304
702
1301
1302
701
1203
1204
604
1201
1202
603
1103
1104
602
1101
1102
601
1003
1004
504
1001
1002
503
903
904
502
901
902
501
803
804
404
801
802
403
703
704
402
701
702
401
603
604
304
601
602
303
EP(322033 32pbs)
EP (322032 16pbs)
When the device is in standby status, press the reset key at the back of the device about 6 seconds,when we hear one long "di", which indicates the reset is successful.
2. Set the number of apartment per floor
When put jumper on "CF"
floor is 4.
3. Room mode setting.
Put jumper on "RM"
position at the back of the device, then set the #F#F (floor), #I#I(room),and pressing the key we needed on the front of the panel, we will hear one
long "di" ,which indicates configuration is successful.
For example: if we want to configure the first key left at the front of the panel as 203. Steps as below:
c) Put the jumper on "CF"
d) Insert the configuration resistors "0" and "2" into "#F#F", "0"and"3"into "#I#I"
e) Press the first key left at the front of the panel, if we hear a long "di" sound and indicate success. If you hear three short "di", indicate wrong configuration.
Pay attention that we can not configure #F#F and #I#I as 00.
f ) Other keys configuration as the steps as c, d, e. if we finished all of the configuration of keys , and then insert jumper into "NA" at the back of the device.
The configuration is finished.
4. SCS address setting mode.
Put jumper on "CF"
at the back of the device. Insert different configuration resistors into the #F#F(floor), #I#I(room),and then press the related key, if we hear a long "di"
sound and which indicates configuration is successful.
For example: if we want to configure the first key left at the front of the panel as 0123. Steps as below:
g) Put the jumper on "CF"
h) Configure #F#F#I#I as 0 1 2 3;
i) Press the first key left at the front of the panel, If we will hear one long "di",indicate success, if you hear three short "di", indicate failure.
The maximum of the SCS configuration address can't be over 4000.
j) The other keys configuration of steps like as g, h ,i. if we finished all of the configuration of keys , and then insert jumper into "NA"
The configuration is finished.
5. " Management center calling" configuration.
The configuration of management center is the same as SCS address setting mode. But the management center address was defined. Means "#F#F #I#I" must be inserted into "40
00" .
6. EEP 's address and keys can be loaded by SF2
Detail information about the operation can be according to the SF2 manual.
, " NN"indicates the number of apartment per floor,for example "02" indicates 2 apartment per floor, and the default number of apartment per
, then Put jumper on "RM"
at the back of the device.
, then Put jumper on "SCS"
at the back of the device
3
at the back of the device.