DEA SYSTEM Spazio 702S Instrucciones De Uso Y Advertencias página 14

Operador electromecánico para puertas seccionales
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Operating instructions and warnings
ensure proper working SPAZIO must be suitably positioned in
relation to the door. DEA System recommended measures are
shown in F3 p. 45. The operator must be chosen according to
the door to automate and sliding properties, weight and width/
height of the door must be assessed.elements to be considered.
WARNING The use of the product under unusual condi-
tions not foreseen by the manufacturer can create situations
of danger, and for this reason all the conditions prescribed in
these instructions must be respected.
4.5
Instructions for risk-free operation
4.5.1 Transport
The SPAZIO gate operator is always delivered packed in bo-
xes that guarantee the product adequate protection. Carefully
read any warnings or instructions for storage and handling pro-
vided on the box.
4.5.2 Installation, assembly and disassembly
For a satisfying laying of the product it is important to define the
entire automatic opening layout (see also "Complete closing as-
sembly"); more specifically, after you have carefully assessed the
features of the place, define model and correct positioning and
then assemble SPAZIO (see F3 page 47):
•Fit the screws in the aluminium-profile slot
•Join the aluminium profiles with the appropriate connecting
rods (DO NOT screw the nuts too strongly)
•Fasten the aluminium guide rail to the motor base by inserting
the centering "tab" and wrap the chain over the draft pinion.
•Put under light tension the chain by operating on the indicated
nut and fasten properly by using the lock nut
•Anchor the metal bracket to the wall aligning it to the center of
the door by using appropriate bushings to anchor the screws
and positioning it at right height
•Bolt the rail to the ceiling by using the M6 nut as shim between
the aluminium-profile and the metal bracket. Cut and
discard unused portion of the brackets.
•Screw or rivet the draft bracket to the door with appropriate
screws/rivets.
•Adjust limit switch cams (see F4 pages 45-46), complete wiring
(see wiring diagram) and then program the built-in control
board as specified below.
WARNING All installation, maintenance, cleaning or
repair operations on any part of the system must be perfor-
med exclusively by qualified personnel with the power supply
disconnected working in strict compliance with the electrical
standards and regulations in force in the nation of installation.
4.5.3 Starting
The installation of the product demands masonry and/or wel-
ding and electrical connection operations using adequate equi-
12
pment for the job in complete respect of accident-prevention
standards and regulations in force in the nation of installation.
Ensure the door to be automated is in good working condi-
MALFUNCTION
When the opening or closing
command is activated the gate
leaf fails to move and the opera-
tor's electric motor fails to start.
When the opening command
is activated, the motor starts
but the door fails to move
The gate moves by fits and
starts, it is noisy, it stops at
half run or it does not start
S P A Z I O
"TROUBLE-SHOOTING" table
The operator is not appropriately powered; check all connections, fuses and power supply
cable conditions and replace or repair if necessary. If the door does not close check that
photocells work appropriately.
Make sure that the motor does not push in the opposite direction, the limit switch electrical
connections might be reversed
The door does not move smoothly; unlock the motor and eliminates any obstacle from
rotating points.
The operator force might be insufficient for the door features; make sure the chosen ope-
rator model is fit.
tions, properly counterbalanced and that the whole structure is
solid. The product is equipped with a built-in control board: see
its instructions. (See paragraph 5.1 and 5.2)
4.5.4 Use
The product is intended to be part of a series of equipment that
make up the door automation. DEA System assumes that it will
always be used in compliance with the standards and regula-
tions in use.
All SPAZIO models are equipped with an unlocking system: just
turn the release handle in the direction shown in F9 page 48;
now if no obstructions hinder its movement, the gate can now
move freely. The door will be locked again automatically with
the first travel thus returning the operator to its normal working
conditions.
4.5.5 Adjustment
SPAZIO is preset with limit switches whose operation must
be adjusted at the job site. In order to adjust the limit switch
cams loosen fixing screw "B", and turn cams "A (Green)" and
"C (Red)" until their respective micro-switches are activated,
then fasten screws in their new position. (see F4 pages 45-46
and follow the instructions given in paragraph 5.2).
Other adjustments can be made directly on the control bo-
ard that controls directly motor speed and can preserve torque
even when operating at low rate, it can control duration of any
slow down speed that may have been selected and anti-crush
safety sensibility as well as other parameters as described in pa-
ragraphs 5.1 and 5.2.
WARNING To avoid premature failure of the operator
program the control board appropriate slow down speed.
4.5.6 Maintenance and repair
Good preventive maintenance and regular inspection ensure
long working life (see also "Warranty"). Consult the "TROUBLE-
SHOOTING" table whenever anomalies are observed in order
to find the solution to the problem and contact DEA System di-
rectly whenever the solution required is not provided.
The inspection/maintenance operations to be routinely sche-
duled in the "complete automatism maintenance register" are:
INTERVENTION TYPE
Chain and rotating joints lubrication
Check screws screwdown
Check chain tension
WARNING All installation, maintenance, cleaning or
repair operations on any part of the system must be perfor-
med exclusively by qualified personnel with the power supply
disconnected working in strict compliance with the electrical
standards and regulations in force in the nation of installation.
CAUSES / SOLUTIONS
PERIODICITY
6 months
6 months
6 months

Hide quick links: