values and restore all default values, proceed as follows:
Instruct.
Function
The control board is ready to receive instructions
Scroll down the parameters until you visualize
P007
Confirm! The control board awaits a further
confirmation
Confirm by pressing on the OK button. The proce-
dure starts
All parameters are now set at their original value
Scroll down the parameters until you visualise "----
". The control board awaits further instructions
•• Safety devices
DEA control board allows fitters to set up installations that
truly comply with European regulations concerning automated
garage doors and gates. More specifically, this control board
allows you to comply with the limits set by the same regulations
as to impact forces in case of collision with obstacles.
DEA control board is equipped with a built-in anti-crush
safety device that, associated to the possibility of tuning up the
motors' speed, allows you to comply with the limits imposed by
the above mentioned regulations in most installations.
In particular, you can adjust the anti-crush safety device sen-
sitivity by properly setting the value assigned to the following pa-
rameters (see also "Personalization of working parameters "):
•P014 motor 1 force in opening: from 30 (min. force, max sen-
sitivity) to 100 (max force, neutralized sensitivity)
•P015 motor 1 force in closing: from 30 (min. force, max sensi-
tivity) to 100 (max force, neutralized sensitivity)
In case the gate structural features do not allow you to comply
with the above force limits, it is possible to use external safety
devices inputs. SIC inputs can be configured by properly setting
parameter no. 18:
•P018= 0 "rib" mode functioning: when the input is activated
the movement direction of the motors is inverted.
•P018=1"photoelectric barriers" mode functioning: when the
input is activated, the motor stops.
If SIC input is unused, it is necessary to short cir-
cuit it to common. If you power external safety devices
through 24VSIC output (terminal no. 22), their proper
working is tested before each manoeuvre.
•• Messages shown on the display
Control board allows you to visualize on the display several
messages concerning its working status and any malfunction:
6 SPARE PARTS LIST
The list of spare parts that can be ordered is a detailed list
that accompanies the exploded view of the product and must be
used to order spare parts.
The following data must always be provided when ordering
spare parts:
• the code of the product (seen on the product label; see F5,
Page 46),
• the part's position number in the exploded view,
• if available, the product's purchase date may be useful in
some cases.
7 COMPLETE CLOSING ASSEMBLY
This chapter illustrates the typical installation of a comple-
te automatism for the purpose of informing and assisting the
installer in the selection of the various parts to be used in com-
pliance with Machinery Directive (2006/42/CE) and European
Safety Standards (EN 12453 - EN 12445 - EN 12604) for gate
Operating instructions and warnings
installation.
The data provided in this chapter are neither complete nor
Display
exhaustive, and DEA System declines all liability for any errors,
omissions or inaccuracies that may occur.
7.1
Minimum level of protection provided by the
safety edge
The risk of getting crushed between the gate and the fence
or wall and/or other fixed parts is among the most serious risks
to be considered when automating a sliding gate is. An appro-
priate type of operating control board must be used according
to the gate type and use against such risk, as provided for by the
quoted regulations (see "OPERATING CONTROL" table).
7.2
Scissoring in side arms
The risk of scissoring on side arms is a relevant risk on au-
tomated overhead doors. The above-mentioned regulations
prescribe the implementation of one of the following solutions
against such risk:
• ensure there is no point of scissoring between the telescopic
arms and the door arms nor with the frame nor with the door
(F10 page 48);
• use adequate protection for your hands in the area;
• this protection is not required if the installation is in a private
home which does not give onto a public area and there is no
timer-set automatic closing.
7.3
Impact in the opening/closing area
Install a pair of photocells on one or the other side of the
gate or on both in order to avoid the risk of impact with the gate
in the closing area. (recommended height: 500 mm) in order to
detect the presence of the test parallelepiped (height: 700 mm)
positioned as shown in F11 on Page 48.
Note. The presence detection test sample is a parallelepiped
with 3 sides with light-coloured reflecting surfaces and 3 sides
with dark-coloured, opaque surfaces.
Make sure there is no conflict when the photocells are instal-
led on both sides. The system working on the gate side where the
test sample is positioned must detect all test objects.
S P A Z I O