5 Function description

5 Function description

6 Putting into operation

EN - 8
The iSTM robot mount serves for accommodating the welding torches in exact
position. The mount is fastened to the robot by means of cylinder head screws
and a plastic intermediate flange. In order to cover the required performance
ranges, there are two different mount versions available – air-cooled and
liquid-cooled. For iSTM mounts, the TCP coordinates are the same as the
coordinates of the corresponding welding torch. For iSTM mounts, a range of
different standard welding torches is available.
The iSTM robot mount is a torch seat without integrated collision protection. The
collision protection or the switch-off of the robot is only possible via the robot
control.
DANGER
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, servicing, dismounting and repair
work, the following instructions must be adhered to:
• Switch off the power source.
• Close off the gas supply.
• Pull the mains plug.
NOTE
• The iSTM mount may only be put into operation by trained personnel.
• For the correct attachment of the iSTM mount and the cable assembly, set
the 4th, 5th and 6th axes of the robot as follows:
4th axis = neutral position, 5th axis = inclined by 10°, 6th axis = neutral
position
This chapter gives you all the information that must be taken into account when
putting the iSTM into operation.