6 Putting into operation
6.4 Attaching the ABIROB
1
®
1
ABIROB
W torch neck
2
Positioning pin
Fig. 7
Attaching the ABIROB
EN - 14
®
W torch neck
3
iSTM fastener
4
Connection module
®
W torch neck
1 Equip the ABIROB
nozzle.
2 Introduce the positioning pin (2) into the marked bore.
®
The ABIROB
W torch neck (1) can only be fastened in this position.
3 Tighten the ABIROB
NOTE
• After using the torch for a prolonged period, it may happen that it can no
longer be disconnected by hand. To do this, a suitable wrench is
available. Do not use pliers to disconnect the torch.
2
5
5
®
W torch neck (1) with tip adaptor, contact tip and gas
®
W torch neck (1) with the nut (5) to the iSTM (3).
3
4
Nut
iSTM