BML-S1F_-A/Q _ _ _ -M_ _ 0 - _ 0-...
Incremental Magnetic Linear Encoder
EU Directive 2004/108/EG (EMC Directive) and EMC law
Noise immunity: EN 61000-6-1/EN 61000-6-2
Emission: EN 61000-6-3/EN 61000-6-4
Intended use
The BML magnetic linear encoder is intended for
communication with a machine control (e.g. PLC). It is
intended to be installed into a machine or system. Flawless
function in accordance with the specifications in the
technical data is ensured only when using original
BALLUFF accessories. Use of any other components will
void the warranty. Non-approved use is not permitted and
will result in the loss of warranty and liability claims against
the manufacturer.
Downloading further instructions
A complete user's guide and the magnetic tape user's
guide can be downloaded from the Internet at
www.balluff.com/downloads-bml or requested via
e-mail from service@balluff.de.
Installation and connection
Construction
Connection type: ...-KA/KD/KF_ _
2×M4
Connection type: ...-KA_ _-S284
~49
Interference in function
Improper assembly of the magnetic tape and sensor head may impair function of the position measuring system and lead to
increased wear or damage to the system.
► All permissible distance and angle tolerances must be strictly complied with.
► The sensor head may not come into contact with the magnetic tape over the entire measuring range. Contact must
also be avoided if the magnetic tape is covered by a cover strip (optional).
► The position measuring system must be installed in accordance with the indicated degree of protection.
External magnetic fields change the functional properties.
► The magnetic tape may not be influenced by strong external magnetic fields (> 30 mT).
► Direct contact with magnetic clamps or other permanent magnets must be avoided.
A too-high tightening torque may damage the housing.
► Tighten the screws with the appropriate tightening torque.
1
english
General safety notes
Installation and startup may only be performed by
trained specialists.
The operator is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the linear encoder will
not result in hazards to persons or equipment.
If defects and unresolvable faults occur in the linear enco-
der, take it out of service and secure against unauthorized
use.
Cable length
2×M4
NOTICE!
File No.
E227256
If a screw with strength class
8.8 is screwed in at
least 10 mm, the max.
tightening torque is 2.3 Nm
(with a tooth lock washer
3.1 Nm).
Secure the screws against
unintended loosening (e.g.
with locking paint).