Software Function Introduction - SATA STV Serie Manual Del Uso

Medidor de torque
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 235
Note:
After the WIFI connection or serial connection with the torque tester is established, all operations of the software are the same.
So the later part of the software introduction does not distinguish which connection mode is working

Software function introduction:

In order to describe the function of software conveniently and clearly, the main interface is specially divided into several areas.
Area A has three operation buttons. The font color of the button in the operation state is white, and the button in the lock state is black.
System Management:
User name and password are required to enter the system management sub- interface. In this sub-interface, users can create, modify
and delete, set wrench information in verification mode and verification value in each stage, set serial port name.
General mode:
This button is a switch button, which will be switched in general mode and verification mode. In general mode, users can test the
wrench up to 25 times. The set torque of the detection can be set on the torque tester and software (Setting Torque in F Area in
Software: Setting Torque Value to be tested, Writing Setting Value Button in A Area to Torque Tester).The test report can be exported
through the Export Report button in H area (the Export Report button can be activated by the number of detection values between 1
and 25 in general mode). This button can be unlocked only when the WIFI connection or serial connection between the software and
the torque test is established in general mode and the data interaction is normal. When switching to verification mode, the wrench
selection drop-down box in area B will be activated, the wrench model created in system management will be displayed in the drop-
down box for selection, and the wrench model to be tested will be selected. The torques to be calibrated in each stage will be displayed
on the rightmost side of area E. At the bottom of the software, there will be an information prompt box to prompt the operator's current
operation steps, etc. To start the operation of verification mode, it is necessary to input the serial number of the wrench at the serial
number of area B before the test can begin. Verification mode test torque is divided into five stages, each stage up to five sets of values,
including a set number of residual effective values (pre-pressure), all can be pre-set in system management. Here, the system
management wrench pre-editing settings are explained. The operation of general mode and verification mode will be described in detail
later.
96473/96474
中文
EN
DE
RU
KO
PT
JA
ES
53

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

9647396474

Tabla de contenido