Technical specifications

Type
Temperature range
Operation
Storage
Relative air humidity
Protection class as per EN 60529 plug
connector inserted or provided with
protective cap
Protection against electric shock
(protection against direct and indirect
contact as per IEC/DIN EN 60204−1)
Electromagnetic compatibility
EMC interference emission
EMC resistance to interference
CPI string extension
Cable length
Modules
1)
Further rules in the manual P.BE−CP−DI02−...
Festo CPV...−GE−CS02−8 0704NH English
1)
CPV...−CS02
−5
+50 °C
−20
+70 °C
95 %, non−condensing
IP65
by means of a PELV circuit
(Protective Extra−Low
Voltage)
see conformity declaration
è www.festo.com
max. 10 m between the CPV
Direct and the last CPI/CP
module or valve terminal
max. 4 modules with to
gether max. 32 inputs and
32 outputs on the CP string