115 VAC Line
Hot Water
Dispenser Outlet
(Continuous Power)
1. Provide Electrical Service
CAUTION: Risk of electrical shock. Use the cord in a properly
grounded outlet to ensure that the thermal safety fuse operates
in the event of heater failure. Do not use a plug adapter.
IMPORTANT! It is recommended that the installation have a Class
A Ground-Fault Circuit-Interrupter (GFCI). The GFCI protects
against line-to-ground shock hazard.
IMPORTANT! Do not use an extension cord with this dispenser.
NOTE: The wall outlet powering the unit must have power supplied
to it continuously. The tank must be located within 30" (76.2 cm) of
the outlet.
NOTE: Use the above electrical diagram if you intend to use the
same wall outlet for the dispenser and your garbage disposal.
112114-2-BE
Wall Switch
The dispenser outlet
must be independent
of the wall switch.
4
Disposer Outlet
(Only Controlled
by Wall Switch)
Kohler Co.