A)
Rigid copper pipe or flexible pipe of
stainless steel
8.5 Replacement of the
connection cable
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to
the voltage and the working temperature.
The yellow/green earth wire must be ap-
proximately 2 cm longer than the brown
(or black) phase wire.
8.6 Building In
min.
450 mm
min.
55 mm
30 mm
480 mm
A)
B)

8.7 Possibilities for insertion

min.
Kitchen unit with door
650 mm
The panel installed below the hob must
be easy to remove and let an easy access
in case a technical assistance intervention
560 mm
is necessary.
A)
B)
Kitchen unit with oven
The electrical connection of the hob and
the oven must be installed separately for
safety reasons and to let easy remove
oven from the unit.
B
supplied seal
supplied brackets
CAUTION!
Install the appliance only on a
worktop with flat surface.
If you install the hob under a
hood, please see the installation
instructions of the hood for the
minimum distance between the
appliances.
A
60 mm
B
Removable panel
Space for connections