Descargar Imprimir esta página

Spraying - Gloria 410 T Serie Instrucciones De Uso

Ocultar thumbs Ver también para 410 T Serie:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 55
Sample computation for checking and
determining dosage of spray com-
pound
Bases:
S praying pressure
1.5 bar
N ozzle
1 mm hollow cone
S praying height
50 cm
D osage
0.5 % (see pesticide
manufacturer's in-
structions)
This means:
Q uantity required
0.42 l/min
S praying width
50 cm
Angle of spray
55°
Q uantity of spray compound
per m
:
0.06 l, = 600 l/ha
2
(see pesticide manufacturer's
instructions)
To mix 1 l spray compound:
1 l water + 5 ml compound
(5 ml = 0.5 % of 1 litre)
W ith a spraying width of 50 cm, a length of
2 m equals a sprayed area of 1 m
.
2
S peed of spraying:
Q uantity sprayed per minute x distance
Q uantity of spray per m
2
0.42 l x 2 m
= 14 m/min.
min. x 0.06 l
The figures on which this sample computa-
tion of the dosage and the quantity of spray
compound required per m
are based have
2
been assumed for that purpose.
30
W hen using the sample computation, the
figures given by the manufacturer of the re-
spective spray compound must be used. If
other nozzles are used, the appropriate tech-
nical data must be taken from the separate
sheet 976 559 (O ptional Accessories
and Nozzle Table) ** and used in the
computation.

Spraying

● T o obtain as even a spray pressure and as
long a spray cycle as possible, set the
pressure regulator on the quick close valve
(10 litre units only) at the minimum per-
missible pressure e.g. 1.5 bar (see
18
Fig.
).
● To start the spraying process push the
operating lever on the quick close valve
down. R eleasing the operating lever will
stop the spraying process immediately.
● If the pressure in the tank falls below the
minimum permissible pressure, work the
pump a little to ensure an even spray. T he
optimum spraying pressure for the 1 mm
hollow cone spray is between 1.5 and 3
bar.
● W hen spraying, ensure that the plants are
wetted evenly.
● P ay attention to the direction of the wind!
D o not spray into the wind.
● The optimum distance from the nozzle to
the plant being sprayed is between 40
and 50 cm.
● W hen using special spraying lances (ex-
tension lances, wide spray lances etc.),
set the pressure higher on the pressure
regulator.

Publicidad

loading

Este manual también es adecuado para:

410 trk serie510 t serie405 t505 t