8. Check the Waterline
CAUTION: Risk of property damage. Before use, return the inlet valve lever to the unlocked (closed)
position to avoid overflow.
NOTE: The waterline is marked inside the tank by a notch and a label.
Turn on the water supply.
Move the lever on the motorized inlet valve into the locked (open) position.
Check the water level in the tank. If the water level is at the marked waterline, return the lever to
the unlocked (closed) position. If adjustments are needed, proceed to the next step.
To adjust the water level, use a flat-blade screwdriver to gently turn the adjustment rod on the inlet
valve. Turning the rod counterclockwise will lower and clockwise will raise the water level.
Return the lever to the unlocked (closed) position.
1035530-2-C
Waterline
Locked
Adjust waterline.
8
Unlocked
Kohler Co.