English
2. remove the screw fixing the fan
grid
3. open the grid
To replace the fan proceed as follows:
1. remove the screws that secure the
fan
2. replace the fan

26. 10 How to reach the thermostatic valve

Procedure
1. remove the tank shelf
2. remove the screws securing the
fan-holder plate
3. move the fan plate
position of the thermostatic valve;
Upon completion of maintenance/cleaning operations, reassemble the parts following the
procedure in reverse order.
Upon assembly completion, restore the electrical power supply.