INSTALLATION
Adjust the valves
To adjust the valves turn the burner knob to
"economic flame" position and ignite the flame.
For COPRECI valves, remove the hob and
adjust the size of an economic flame with a
screwdriver.
40
In order to check the flame, heat up the burner
on a full flame for about 10 min., and then
turn the burner knob to an economic flame
position. The flame should not go out or jump
on the nozzle. However, if it does, readjust of
the valves.
Conversion of the appliance to a
different gas type than specified by
the manufacturer on the nameplate
or purchasing an appliance that is
intended for a different gas type than
provided in the building, is entirely
up to the user and installer.