Pedestal Mounting Instructions (LXMMPED + LXMM)

Mounting Instructions

Rain Bird Pedestal and Controller
Cabinet (LXMMPED + LXMM)
Your pedestal and controller cabinet can be used for in-
door or outdoor installations of Rain Bird controllers. The
LXMMPED kit includes a pedestal and a controller cabinet
to be mounted on top of the pedestal. Please note that
the cabinet can also be purchased as a standalone prod-
uct (LXMM) and can be wall mounted if desired. Pedes-
tals are not required for wall mounted cabinets.
The pedestal should be mounted on a level concrete base
with the top of the base at least 2" above ground level.
We suggest construction of a base of at least 9" width x
18" length x 11" depth (23 x 46 x 28 cm). Please read all
instructions below prior to construction of the base! A
single base can be used for multiple pedestals if desired.
If multiple pedestals will be mounted on a single concrete
base, at least 5" (12.7 cm) space in every direction should
be allowed between each pedestal.
Pedestal Mounting Instructions:
1. Prior to pouring the concrete for the base, position a sweep elbow of maximum 1.5" (3.81 cm) width and additional sweep
elbows of maximum ½" (1.27 cm) width for power and/or modem connections if needed (see Figure 1).
2. It is very important to ensure the sweep elbows terminate inside the footprint of the pedestal base, which is marked as the
shaded area of the included positioning template. Sweep elbows for power should be installed to the left side of the base
and elbows for other wiring to the right (see Figure 2).
2.8
2.3
2
ESP-LX Modular Pedestal and Controller Cabinet - Mounting Instructions
Pedestal
Positioning Template
Anchor Bolt
4
AC line input
conduit
(class 1 wiring)
Anchor Bolt
18.0
Figure 2
½" conduit for 117 volt line input wires
and pump start wires (class 1 wiring)
Figure 1
Anchor Bolt
8.6
Valve control wires
phone access line
conduit (class 2 wiring)
Anchor Bolt
13.5
Up to 1½" conduit for valve
control wires (class 2 wiring)
½" conduit for phone
access line input (optional)
(4x) anchor bolts
9.0
3.5
2.7
2.7
2.8