7. Key to symbols

See user instructions
Date wheel
Recycling symbol
CE approved by INSPEC Certification Ltd
8. Approvals
CE/EN
The SR 200 with polycarbonate visor is approved in ac-
cordance with EN 136:1998, class 3.
The plastic visor has been tested against EN 166:1995,
class B.
The SR 200 with glass visor is approved in accordance
with EN 136:1998, class 2.
The SR 200 in combination with fan unit SR 500/SR 700 is
approved in accordance with EN 12942:1998, class TM3.
The SR 200 in combination with compressed air at-
tachment SR 307 is approved in accordance with EN
14594:2005.
The SR 200 in combination with fan unit SR 500 EX is
approved in accordance with EN 12942:1998, class TM3,
ATEX Directive 94/9/EC and the IECEx scheme.
Australian StandardsMark
The full face mask SR 200 is tested and certified to
comply to AS/NZS 1716:2012. The StandardsMark is
issued under licence by SAI Global Pty Limited LIC No.
766 (ACN 108 716 669) ("SAI Global").
32
ATEX-codes:
II 2 G Ex ib IIB T3 (SR 200 with glass visor).
II 2 G Ex ib IIA T3 (SR 200 with PC visor).
II 2 D Ex ibD 21 T195°C (SR 200 with PC/glass visor).
Key to ATEX markings:
Explosive area symbol.
Equipment group (explosive atmospheres other
II
than mines).
2G
Equipment category. (2=High level of protection,
zone 1. G=Gas).
2D
Equipment category. (2=High level of protection,
zone 21. D=Dust).
Ex
Explosion protected.
ib/ibD
Type of ignition protection (Intrinsic safety).
21
Zone with combustible dust.
IIA
Explosion group Propane.
IIB
Explosion group Ethylene.
Temperature class, gas. (Maximum surface
T3
temperature +200 °C).
T195°C Temperature class, dust. (Maximum surface
temperature +195 °C).
IECEx-codes:
Ex ib IIB T3 (SR 200 with glass visor).
Ex ib IIA T3 (SR 200 with PC visor).
Ex ibD 21 T195°C (SR 200 with PC/glass visor).
Key to IECEx markings:
Ex
Explosion protected.
ib/ibD
Type of ignition protection (Intrinsic safety).
IIA
Explosion group Propane.
Explosion group Ethylene.
IIB
Zone with combustible dust.
21
Temperature class, gas. (Maximum surface
T3
temperature +200 °C).
T195°C Temperature class, dust. (Maximum surface
temperature +195 °C).
The EC type approval certificates have been issued by
Notified Body No. 0194.
For address, see back-cover.
The ATEX/IECEx type approval certificates have been
issued by Notified Body No. 0470
NEMKO AS, Gaustadalleen 30, PO Box 73, Blindern,
N-01314 Oslo, Norway.