or sharp tools.
The liquid detergent for cleaning
the hob must have certain che-
mical features: pH greater than 12,
without chlorides/ammonia, viscosity
and density similar to water. Use
non-aggressive products for cleaning
the inside and outside of the applian-
ce (use detergents on the market for
cleaning steel, glass and enamel).
Carefully read the indications car-
ried on the labels of the products
used. Wear protective equipment
suitable for the operations to be perfor-
med (see the protective equipment car-
ried on the package label).
In the event of prolonged inacti-
vity, besides disconnecting the
supply lines, you must thorou-
ghly clean all the inside and outside
parts of the appliance.
Wait for the temperature of the
appliance and all its parts to
cool off, so that the operator is
not burnt.

DAILY CLEANING

to apply the liquid detergent on the
whole surface (cooking compartment,
lid and all exposed surfaces) and using
a non-abrasive sponge, clean the entire
appliance thoroughly by hand.
When finished, rinse abundantly with
tap water (do not use pressurised direct
water or steam cleaners jets for cleaning
operations). Empty the water from the
cooking compartment with the drainage
gate valve. Open the drainage gate
valve only after having made sure that
THE PRESENT MANUAL IS PROPERTY OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
Remove everything
f r o m t h e c o o k i n g
compartment.
Use a standard sprayer
the pipe is free from obstructions.
Carefully dry the cooking compartment
with a non-abrasive cloth. If necessary,
repeat the operations described above
for a new cleaning cycle.
When these operations have been
done successfully, close the drainage
gate valve.
For the parts removed, clean with
detergent and tap water, dry carefully
and reposition in the correct order.
Replace the parts removed in
the correct order (if necessary)
CLEANING FOR PROLONGED
DEACTIVATION/ See chapter 5 / Daily
decommissioning / Prolonged decom-
missioning. Air out the appliances
and rooms regularly
SUMMARISED TABLE:
QUALIFICATION - OPERATION -
FREQUENCY
Before proceeding with the ope-
rations, see chap.2 "Duties and
qualifications"
Should a problem occur, the ge-
neric operator performs the first
search and, if qualified, elimina-
tes the cause of the problem and re-
stores the appliance correctly.
If the problem cannot be resol-
ved, turn the appliance off, di-
sconnect it from the electrical mains
and shut all the supply valves. Then
contact authorized customer service.
The authorized maintenance te-
chnician intervenes when the
generic operator was not able to pin-
point the cause of the problem, or
whenever restoration of correct ope-
ration of the appliance entails execu-
ting operations for which the generic
operator is not qualified.