6. Insert an electrical wire strain relief into the
opening in the opposite side of the pressure
switch.
7. Thread the cable from the power supply through
the strain relief and tighten both screws on the
strain relief. Do not crush wire.
8. Connect the two wires from the power supply to
the two outside terminals on the pressure switch.
9. Connect the green ground wire from the power
supply to the remaining green ground screw in
the pressure switch, and re-attach the pressure
switch cover.