Zoeller 1463-0006 Instrucciones página 49

Ocultar thumbs Ver también para 1463-0006:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2. Insert an electrical wire strain relief into the
opening in the side of the pressure switch closest
to the motor.
3. Thread the cable from the pump motor through
the strain relief into the pressure switch cavity
and tighten both screws on the strain relief. Do
not crush wire.
4. Connect the two motor wires of the motor cable
to the two inside terminals on the pressure
switch.
5. Connect the green ground wire from the motor
cable to one of the green ground screws at the
bottom of the pressure switch.
2
3
4
5
11
© 2020. All rights reserved.
IL1372
Wire from
motor
IL1373
Wire from
motor
IL1374
Wire from
motor
IL1375
Ground Screws

Publicidad

Tabla de contenido
loading

Tabla de contenido