Secondary Parameters - LORCH T-Serie BasicPlus Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
Starting up
14.3

Secondary parameters

Danger due to electric shock!
If function HF-ignition is selected, a high ig-
nition voltage is present at the torch.
Never touch the welding electrode or parts
conducting welding current when the de-
vice is switched on.
The secondary parameters are set separately:
 Press the welding process 30 and mode 47 buttons briefly
simultaneously.
9 The 7-segment display 38 alternately displays the code of
the secondary parameter and its value.
 Press the main parameter button 48 until the desired pa-
rameter appears.
 Use knob 41 to set the desired value.
 Briefly press the welding process 30 or mode 47 button to
end this mode.
9 The changed values are accepted.
For more effective adjustment, all welding
i i
parameters can be changed even during the
welding process.
Parameter
Hotstart IS
1
of main current
Hotstart time tS
1
Arc dynamic
1
The welding current increases automatically as the welding volt-
age is reduced. The arc dynamic indicates the ratio between the
main current and the automatic increase.
Start current
2
of main current
Start current time
2
Pulse duty factor 
2
(only for pulse
mode)
Indicates the percentage ratio between main current I1 and auxil-
iary current I2. If the value set is 30, the ratio is 30 % I1 to 70 % I2.
Final current
2
of main current
Final current time
2
AC balance
3
AC frequency
30 - 200 Hz
3
Positive current
10 - 200 %
correction
2, 3, 4
Ignition using the Positive current is used for optimum dome for-
mation in TIG AC welding. This positive current is preset in the unit
and can be increased or reduced by the quoted percentage.
01.21
Factory
Range
setting
5 - 200 %
125
0 - 20 sec.
1,0
0 - 200 %
100
5 - 200 %
50
0 - 20 sec.
0,1
1 - 99 %
50
5 - 200 %
25
0 - 20 sec.
0,2
10 - 90 %
35
60
100
Parameter
gnition peak
I
correction
2, 4
The ignition peak current is set after ignition to provide stabilisa-
tion of the arc. This ignition peak current is preset in the unit and
can be increased or reduced by the quoted percentage.
HF On/Off
2
HF ignition is a contactless ignition brought about by high-voltage
impulses.
Powermaster LED 3
Powermaster LED 4
All Powermaster torches of the i-LTG/i-LTW – series have two free
programmable parameter spaces. Depending on the type of weld-
ing machine and operating mode, different parameters can be
selected (please also see „14.4 Powermaster parameters" on page
40).
Powermaster LED
lock
ON: mode button at the torch of the i-LTG/i-LTW serie is locked. By
pressing the mode button for 2 seconds, the button is unlocked
for 15 seconds. If the start/stop-button is pressed during these 15
LED/
seconds, the mode button is immediately locked.
Code
up / down lock
ON: during the welding (I>0), the up / down buttons at the torches
of the i-LTG/i-LTW-series are locked.
Torch protect
2
ON: if a torch of the i-LTG/i-LTW –series is used, only a welding
current up to the max. torch strain limit can be adjusted at the
welding machine.
cooling permanent
ON
2
AUT: water cooling unit (WUK) switches on / off automatically.
ON: after the first current (I>0) the WUK is switched on and stays
on permanently.
Version info
Tab. 3:
Secondary parameters
Only for electrode welding process
1)
Only for TIG welding process
2)
3)
Only for TIG welding process
4)
Factory setting for electrodes -Ø 2.4 mm
for electrodes-Ø < 2.4 mm: Reduce parameter value
for electrodes-Ø > 2.4 mm: Increase parameter value
909.2669.9-02
Factory
Range
setting
10 - 200 %
100
On - Off
On
I2
all Powermaster param-
eters
OFF, ON
OFF
OFF, ON
OFF
OFF, ON
OFF
Aut = Auto, On
Aut
-
LED/
Code
-
-
- 39 -

Publicidad

Tabla de contenido
loading

Tabla de contenido