Main Water Circuit; Sensors; Expansion Vessel; Circulation Pump - Sime Brava Slim 40 BF Manual De Instalación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1.6

Main water circuit

1
2
3
4
6
8
13
M
U
KEY:
M System delivery
R System return
U Domestic hot water outlet
E Domesti hot water inlet
S Safety valve outlet
G Gas supply
Fan
1
Heat exchanger (mono-thermal)
2
Dual sensor (thermal safety/delivery)
3
Combustion chamber
4
Gas valve
5
Domestic hot water heat exchanger
6
Domestic hot water sensor
7
Diverter valve
8
Automatic bleed valve
9
Pump
10
Domestic hot water flow meter
11
Domestic hot water filter
12
System filling
13
System relief valve
14
Water pressure transducer
15
Boiler drain
16
System expansion vessel
17
1.7

Sensors

The sensors installed have the following characteristics:
– Dual sensor (thermal safety/output) NTC R25°C; 10kΩ β25°-
85°C: 3435
– domestic hot water sensor NTC R25°C; 10kΩ β25°-85°C: 3435
– external sensor NTC R25°C; 10kΩ β25°-85°C: 3435
Correspondence of Temperature Detected/Resistance
Examples of reading:
TR=75°C → R=1925Ω
TR=80°C → R=1669Ω.
76
17
5
9
15
14 S
7
11
12
G
E
R
TR
0°C
1°C
0°C 27279
26135
25044
17959
17245
16563
10°C
20°C
12090
11634
11199
30°C
8313
8016
40°C
5828
5630
50°C
4161
4026
3021
2928
60°C
70°C
2229
2164
80°C
1669
1622
1266
1232
90°C
100°C
973
1.8

Expansion vessel

The expansion vessel installed on the boilers has the following
characteristics:
10
Description
Total capacity
Prefilling pressure
16
Useful capacity
Maximum system content (*)
(*) Conditions of:
Average maximum temperature of the system 85°C
Start temperature at system filling 10°C.
Fig. 3
m
CAUTION
– For systems with water content exceeding the
maximum system content (as indicated in the
table) an additional expansion vessel must be
prearranged.
– The difference in height between the relief valve
and the highest point of the system cannot exceed
6 metres. If the difference is greater than 6 metres,
increase the prefilling pressure of the expansion
vessel and the system when cold by 0.1 bar for each
meter increase.
1.9

Circulation pump

The flow-head performance curve available for the heating
system is shown in the graph below.
RESIDUAL HEAD (mbar)
600
500
400
300
200
100
0
0
200
2°C
3°C
4°C
5°C
6°C
7°C
24004
23014
22069
21168
20309
15912
15289
14694
14126
13582
10781
10382
9999
9633
9281
7731
7458
7196
6944
6702
6470
5440
5258
5082
4913
4751
4595
3897
3773
3653
3538
3426
3319
2839
2753
2669
2589
2512
2437
2101
2040
1982
1925
1870
1817
1577
1534
1491
1451
1411
1373
1199
1168
1137
1108
1079
1051
U/M
Brava Slim 40 BF
l
kPa
bar
l
l
400
600
800
1000 1200 1400
EN
8°C
9°C
19489
18706
13062
12565
8945
8622
6247
6033
4444
4300
3216
3116
2365
2296
1766
1717
1336
1300
1024
998
9,0
100
1,0
5,0
124
40 BF
1600
FLOW (l/h)
Fig. 4