Main Water Circuit; Sensors; Expansion Vessel - Sime BRAVA ONE HE 25 Manual De Instalación Y Mantenimiento

Ocultar thumbs Ver también para BRAVA ONE HE 25:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
1.6

Main water circuit

1
2
3
4
6
5
11
12
13
19
20
Sc
M
U
KEY:
M System delivery
R System return
U Domestic hot water outlet
E Domesti hot water inlet
S Safety valve outlet
G Gas supply
Sc Condensate outlet
Condensing heat exchanger
1
Combustion chamber
2
Ventilator
3
4
Thermal safety thermostat
Delivery sensor
5
Domestic hot water heat exchanger
6
Water pressure switch
7
Automatic bleed valve
8
Pump
9
System expansion vessel
10
Diverter valve
11
12
Automatic by-pass
Domestic hot water sensor
13
Gas valve
14
Domestic hot water flow meter
15
Domestic hot water filter
16
Boiler drain
17
System relief valve
18
System filling
19
20
Condensate siphon outlet
All manuals and user guides at all-guides.com
10
8
9
7
17
15
14
18
16
G
E
R
S
Fig. 3
1.7

Sensors

The sensors installed have the following characteristics:
– Dual sensor (thermal safety/output) NTC R25°C; 10kΩ
β25°-85°C: 3435
– domestic hot water sensor NTC R25°C; 10kΩ β25°-85°C:
3435
– external sensor NTC R25°C; 10kΩ β25°-85°C: 3435
Correspondence of Temperature Detected/Resistance
Examples of reading:
TR=75°C → R=1925Ω;
TR=80°C → R=1669Ω.
TR
0°C
1°C
2°C
3°C
4°C
0°C 27279
26135
25044
24004
23014
10°C
17959
17245
16563
15912
15289
20°C
12090
11634
11199
10781
10382
30°C
8313
8016
7731
7458
7196
5828
5630
5440
5258
5082
40°C
4161
4026
3897
3773
3653
50°C
60°C
3021
2928
2839
2753
2669
70°C
2229
2164
2101
2040
1982
80°C
1669
1622
1577
1534
1491
90°C
1266
1232
1199
1168
1137
100°C
973
1.8

Expansion vessel

The expansion vessel installed on the boilers has the following
characteristics:
Description
Total capacity
Prefilling pressure
Useful capacity
Maximum system content (*)
(*) Conditions of:
Average maximum temperature of the system 85°C
Start temperature at system filling 10°C.
m
CAUTION
– For systems with water content exceeding the ma-
ximum system content (as indicated in the table)
an additional expansion vessel must be prearran-
ged.
– The difference in height between the relief valve
and the highest point of the system cannot exceed
6 metres. If the difference is greater than 6 me-
tres, increase the prefilling pressure of the expan-
sion vessel and the system when cold by 0.1 bar
for each meter increase.
5°C
6°C
7°C
8°C
9°C
22069
21168
20309
19489
18706
14694
14126
13582
13062
12565
9999
9633
9281
8945
8622
6944
6702
6470
6247
6033
4913
4751
4595
4444
4300
3538
3426
3319
3216
3116
2589
2512
2437
2365
2296
1925
1870
1817
1766
1717
1451
1411
1373
1336
1300
1108
1079
1051
1024
998
Brava One HE
U/M
25
30
l
9,0
kPa
100
bar
1,0
l
5,0
l
124
59

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Brava one he 3081122008112202

Tabla de contenido