Key
F08
01
Electronics voltage too low, check control terminals.
04
Electronic voltage too high, check wiring of control terminals.
F11
00
Output frequency too high, check settings.
F12
01
Diagnosis error of function STO; at least one of the shut-down paths S1IND and S7IND is
defective. Check the devices connected to the shut-down paths; check wiring and EMC.
04
Software self-diagnosis has detected an internal error. Parameter
GB
describes the cause of the error. Consult BONFIGLIOLI customer service.
05
Fault message of 5-second monitoring. Shut-down paths S1IND and S7IND were not actuated at
the same time, but with an offset of more than 5 seconds. Check addressing of shut-down paths or
control of protection provision.
F13
00
Earth fault at output, check filter and cabling.
42
Electronic voltage
Meaning
Output frequency
Safety function STO

Mains connection

Quick Start Guide AEC