Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

6 Technical Data

6.1
Size 3 and 4 AEC 9,7...22,2 kVA
Type
AEC 401
Size
Output mains side,at 400 V mains voltage
1
Output power
Output current
Recommended
2
motor shaft power
Voltage
Frequency
Protection
THD
Shift factor
Switching frequency
Fuses
Output, brake resistor
Minimum brake resistor
Recommended brake resistor
(770 V)
Mechanics
H
Dimensions
W
D
Weight (approx.)
Terminals
Protection
Installation
Ambient conditions
Power dissipation (4 kHz switching
frequency)
Cooling agent temperature (air)
Storage temperature
Transport temperature
Relative air humidity
DC link
Max. DC input voltage
Optional Components
Line choke (u
=4%)
k
RFI (Radio interference filter)
Sine filter (u
=8%)
k
1
At 400 V Mains voltage
2
The recommended motor shaft power takes into account the maximum occurring regenerative power output of
AC induction motors.
3
Via Parameter
Fixed Percentage 1
06/13
-19
3
kVA
9.7
12.5
A
14
kW
5.5
V
Hz
Short circuit proof and earth fault proof
%
-
kHz
-
48
80
250
mm
100
200
kg
3
2
mm
0.2 ... 6
0.2 ... 6
-
-
W
160
°C
0 ... 40 (3K3 DIN IEC 721-3-3)
°C
°C
Operation:
%
Storage:
V
Overvoltage switch off at > DC 800 V
-
-
-
520
Quick Start Guide AEC
-21
-22
-23
3
3
4
15.2
17.3
18
22
25
7.5
9.2
11.0
320 ... 460
45 ... 66
< 3%
3
cos φ adjustable
4, 8, 12, 16
external
48
48
32
58
48
48
250
250
250
100
100
125
200
200
200
3
3
3.7
0.2 ... 6
0.2 ... 16 0.2 ... 16
IP20 (EN60529)
vertical
210
260
280
-25 ... 55
-25 ... 70
max. 85
non-condensing
5 ...95
external
external
external
-25
4
22.2
32
15.0
GB
32
32
250
125
200
3.7
365
43

Publicidad

Tabla de contenido
loading

Tabla de contenido