9. Specifications
Device Type
Housing&Mounting
Protection Clas
Weight
Enviromental Ratings
Storage / Operating Temperature
Storage / Operating Humidity
Installation
Overvoltage Category
Pollution Degree
Operating Conditions
Supply Voltage and Power
Thermoresistance Sensor Input
Accuracy
Sensor Break Protection
Sampling Cycle
Control Form
Relay Outputs
Display
LED Displays
Internal Buzzer
Upprovals
: Hatcher Controller
: 76 mm x 34.5 mm x71 mm Plastic housing for panel
Panel cut out is 71 x 29 mm.
: NEMA 4X (Ip65 at front,Ip20 at rear).
: Approximately 0.2 Kg
: Standart,indoor at an altitude of less than 2000 meters with
none condensing humidity.
o
o
: -30 C to +80 C / -20 C to +70 C
: 90 % max. (None condensing)
: Fixed installation
: II.
: II, office or workplace, none conductive pollution
: Continuous
V ±
:
230V
( %15) 50/60Hz - 1.5VA
V ±
: 115
V
( %15) 50/60Hz - 1.5VA
V ±
: 24
V
( %15) 50/60Hz - 1.5VA
W ±
: 24
V
( %15) 50/60Hz - 1.5VA
: 10-30
VZ 1.5W
: PT-100 (IEC751) (ITS 90)
: ± 1 % of full scale for thermoresistance
: Upscale
: 3 samples per second
: ON / OFF or PID
: 5 A@250 V V at Resistive Load (Heating Output)
: 3 A@250 V V at Resistive Load
(Alarm and Egg tray rotator output)
(Electrical Life : 100.000 operation (Full Load))
: 14 mm Red 4 digit LED Display
: S (Yellow), P (Yellow), C (Green), F(Green), Alarm (Red),
Egg Tray Rotator Output (Red), Heating Output (Red),
:
83dB
:
,
o
o
o
o
15