EN

4.16 - Using the display programmer

To customise the programmer's language, proceed as follows:
OPTIONS
DISPLAY
N.B.: When the display is turned on for the fi rst time, the user
will be prompted to select a language. Press ▲ or ▼ to select
the desired language and then confi rm with V.
If no language is selected (press the X key), the control unit will
use the default language (ENGLISH) until the next power-on.
In normal mode, i.e. when the system is powered on normally
and the display programmer is connected, press X until the
wording "Key Automation" is displayed. In this way, you will
be able to view the following status messages:
EVENT
opening
ventilation opening
closing
automatic closing
stop in closing
stop in opening
open
open in ventilation
closed
programming
obstacle
photo!
sensitive edge!
partial opening
partial automatic closing
ventilation automatic closing
FLASH/LED error
phototest error
limit switch error!
memory error

4.17 - KUBE PRO / KUBE wireless module connection

Before carrying out any operation, power off the equipment.
Remove the plastic protection cover of the KUBE module connector.
Remove the plastic shells (FIG. 49) and insert the card in its special
input slot (FIG. 50).
ATTENTION !
Once removed from its container, handle the KUBE module
with extreme care.
ATTENTION !
Carefully check the position of the KUBE module on the control
unit connector (FIG. 50).
With the KUBE PRO and DYL programmers it is possible to change,
in addition to the parameters (TAB. 3), the following parameters:
opening speed *
slowing speed in opening *
closing speed *
slowing speed in closing *
slowing extent in opening *
slowing extent in closing *
12
LANGUAGE
SELECTION
DESCRIPTION
Door opening
Door opening for ventilation
Door closing
Open door with timed closing active
Door stopped in closing phase
Door stopped in opening phase
Door fully open without automatic closing
Door open in ventilation without automatic closing
Door fully closed
During the programming phase
Detected motor obstacle
Photocell operation
Sensitive edge operation
Partial opening in progress
Partial door opening with active timed closing
Open door in ventilation with active timed closing
FLASH and LED output overload
Phototest error detected
Limit switch/mechanical stop error detected
Memory error detected
KEY AUTOMATION
SCROLL UP
CANCEL
SCROLL DOWN
2 fast fl ashes + pause + 1 fl ash
4 fast fl ashes + pause 3 times
2 fast fl ashes + pause 3 times
5 fast fl ashes + pause 3 times
6 fast fl ashes + pause 3 times
3 fast fl ashes + pause 3 times
8 fast fl ashes + pause 3 times
10 fast fl ashes + pause 3 times
phototest
sensitive edge test
partial opening extent
garage ventilation function extent
partial automatic closing time
ventilation automatic closing time
fl ashing operation mode
pre-fl ashing time
light intensity at end of movement
integrated courtesy light operation
operation after power failure
fl ashing activation for maintenance
default
input lock with password
receiver lock with password
stop contact
to change follow the instructions on the screen.
ATTENTION !
* After adjusting the parameter it is mandatory to control at
least two complete operations to allow the control unit to store
the motor stress throughout the stroke
CONFIRM
FLASHING INDICATION AND
CONTROL UNIT CONTROL LEDS

Publicidad