Descargar Imprimir esta página

jbc RA 5150 Manual De Instrucciones página 3

Ocultar thumbs Ver también para RA 5150:

Publicidad

Idiomas disponibles

Idiomas disponibles

ENGLISH
FEATURES
Station composition
TA 5120 EU:
TA 5120 UK:
TA 5120 USA:
-
Analog Control Unit 230V
-
Analog Control Unit 120V
-
Desoldering iron 75W
-
Desold. iron stand UD 1500
-
External desoldering air filter
-
Set of tools and
replacement filters
-
Tip removal device
-
Instructions manual
Weight of packaged equipment: 3,6 kg
Besides the desoldering iron supplied with this
station, the Control Unit will also take the 20W
Ref. 3000000, 50W Ref. 3010000, 60W
Ref. 3020000 with solder feed and 70W
Ref. 3070000 soldering irons.
Equipotential terminal
Desoldering connector
Ref. 5120200
Ref. 5120201
Ref. 5120100
Ref. 5230200
Ref. 5230100
Ref. 3040000
Ref. 0290150
Ref. 0781184
Ref. 0781181
Ref. 0114108
Ref. 0965405
temperature selection
External desoldering air filter
The desoldering iron is connected to the station following the below procedure:
The cable connection of the desoldering iron is connected to the desoldering connector
of the station and the vacuum hose is connected to the external desoldering air filter,
which is connected to the vacuum connection of the station. Very important, it is
essential to connect the mentioned filter to prevent from damaging the vacuum pump.
Control Unit technical data
1. Station maximum power: 100W
2. Safety transformer with mains separator:
230V/24V 50Hz - 120V/24V 60Hz
3. Temperature range: from 100 till 400°C.
4. Programmed temperature accurate: ± 5%.
5. Green LED temperature adjustment optical
control.
6. Abides the CE standards for electrical
security, electromagnetical compatibility and
antistatic protection.
7. Equipotential connector and the tool tip are
connected to station mains ground supply for
ESD protection.
Temperature adjustment for special tips
The temperatures on the dial are set for the 75W
desoldering iron of with tip 20 DE, which is included
in the equipment. A change of tip or soldering iron
model could involve a variation of ± 7% in the set
temperature.
Desoldering
Spare filters
Ref.0781046
Ref.0781184
2
% Vacuum indicator
and obstruction degree
in the suction circuit
Aspiration inlet

Publicidad

loading

Este manual también es adecuado para:

Ta 5120