(3). If gap still exists between ceiling and decoration panel after tightening the screws, readjust
the height of the indoor unit. (Fig.33)
(4).
5.5.2 Installing the Panel
(1).
(2). Latch other two hooks.
(3). Tighten four hexagonal screws under the latches about 15mm.
(4). Adjust the panel along the direction indicated by the arrow as shown in Fig.35.
(5). Tighten the screws until the thickness of the sealing material between the panel and the
indoor unit reduces to 5-8cm.
DC Inverter Free match Series Cassette Type Unit
Fig.33
Fig.34
Fig.34
26
.