15. DATA VIEW display
During and after a completed cycle (charge / discharge) process and EQUALIZE process the
charger can display much additional information about your battery and the current process.
Press the DATA button to move to the DATA VIEW display.
You can leaf through the DATA VIEW display by pressing the INC button to move forward, and the
DEC button to move back.
Press the DATA button a second time to return to the previous display.
15.1. The DATA VIEW display for the Lithium program group
In the Lithium program group the DATA VIEW display shows you the following data:
Current input and output voltage of the MULTIcharger LN-6015 EQU
Individual cell voltages of the Lithium battery connected to the charger (only if the balancer lead
is connected)
Highest and lowest individual cell voltages
Display of each individual cell voltage compared with the average of all the individual cell
voltages. If you press the ENTER button at this display, the number for the xth cell flashes, and you
can move to the next or preceding cell by pressing the INC or DEC button. In this way you can
display the individual cell voltages to an accuracy of three decimal points.
Display of the highest measured voltage of the battery connected to the charger during the
charge process, and the average battery voltage during the discharge process.
Charged-in capacity during the charge process, and capacity removed from the pack during the
discharge process.
INPUT
= 12.12V
OUTPUT = 11.95V
DEC
INC
ChgCAPA= 22mAh
DchCAPA= 00mAh
MULTIPLEX Modellsport GmbH & Co.KG • Westliche Gewerbestraße 1 • D-75015 Bretten • www.multiplex-rc.de
MULTIcharger LN-6015 EQU Operating Instructions
INC
3.95 4.00 4.05
0.00 0.00 0.00V
DEC
INC
CHG PEAK =12.00V
DCHG AVR =00.00V
DEC
INC
LCB-MAX =4.048V
LCB-MIN
DEC
DEC
INC
LCB-[01]
LCB-AVG =4.000V
DEC
ENTER
DEC
LCB-[02]
LCB-AVG =4.000V
=3.950V
INC
=3.950V
INC
=4.004V
Page 21/24