15.2. The DATA VIEW display for the NiXX and Lead program group

In the Nickel and Lead program group the DATA VIEW display shows you the following data:
Current input and output voltage of the MULTIcharger LN-6015 EQU
Display of the highest measured voltage of the battery connected to the charger during the
charge process, and the average battery voltage during the discharge process.
Charged-in capacity during the charge process, and capacity removed from the pack during the
discharge process.
INPUT
= 12.12V
OUTPUT = 11.95V
DEC

16. User-defined settings

Press the INC and DEC buttons simultaneously to move to the user-defined settings menu.
Press the INC and DEC buttons to leaf forward and back within the menu.
Pressing the ENTER button accepts the desired setting. As soon as the appropriate display
flashes, you can change the value by pressing the INC and DEC buttons.
Press the BATT TYPE button to return to the charge program groups.
KEY BEEP
ON
ENTER
DEC
INC
KEY BEEP
ON
Switch button beeps
ON / OFF
MULTIPLEX Modellsport GmbH & Co.KG • Westliche Gewerbestraße 1 • D-75015 Bretten • www.multiplex-rc.de
MULTIcharger LN-6015 EQU Operating Instructions
INC
CHG PEAK =11.97V
DCHG AVR =11.81V
DEC
INC
BUZZER
ON
DEC
ENTER
DEC
BUZZER
ON
Switch buzzer ON /
OFF
INC
DEC
INC
DEC
INC
ChgCAPA= 22mAh
DchCAPA= 00mAh
INC
INPUT POWER LOW
Cut Off:
11.0 V
ENTER
DEC
INC
INPUT POWER LOW
Cut Off:
11.0V
Set low input voltage
threshold at which a
warning is triggered.
To protect your car
battery you should
only use this function
in exceptional cases.