Maintenance

Cleaning Air Cleaner
Cleaning
Clean the air cleaner with the dust collector or water to remove dusts.
For too much dust, use the fan or directly spray the special cookware detergent on the air
inlet grid, and then clean it with water after 10 minutes.
(A) remove dust with dust collector.
(B) for too much dust, use soft-hair brush and mild detergent to clean.
(C) throw off water and then dry it at cool places.
Don t clean it with hot water of over 50
Don t dry it on the fire, or the cleaner might cause fire.
Installing air cleaner and air inlet grid:
CBV005-016,CCV018-048
1. Mounting the gauze: opposite to the ways of dismantling the gauze (as shown in Fig. 3 above).
2. Mounting the air inlet grid: as shown in the right figure, nip the locks on the grid as directed by
arrows, put the side with the lock device into the lock port, and then put the side with locks
into the panel frame. Release the locks to position the grid after determining that the grid is
abutting upon the bottom of the panel frame.
Attention
to avoid fading or distortion.
lock device
locks
insert air inlet grid
6
lock port