Troubleshooting (cont.)
CAUTION: Risk of product damage. This product contains
sensitive electronic components. Use care not to damage pins and
connectors during troubleshooting.
CAUTION: Risk of product damage. Do not insert anything other
than the sensor wire into the sensor wire connector (phone jack) on
the circuit board.
NOTE: For service parts information, visit your product page at
www.kohler.com.
Faucet Troubleshooting Table
Symptoms
Probable Causes
1. No water
A. The supply
flow.
stops are
closed.
B. Handle is in
the closed
position.
C. The hot
and/or cold
supply hose
is kinked.
D. The outlet
hose is
kinked.
E. Handle LED
is not lit.
F.
Sensor LED
is not lit.
G. One or more
screens are
clogged.
2. Low water
A. The supply
flow.
stops are
partially
closed.
B. Handle is
partially
closed.
1186051-2-D
Recommended Action
A. Confirm the supply stops are
open.
B. Rotate the handle to the open
position. Refer to the "Faucet
Operation" section.
C. Confirm the supply hoses are
not kinked. If coiled, maintain
an inside diameter of 3" (76
mm).
D. Confirm the solenoid valve is
located within 7" (178 mm) to
8" (203 mm) from the faucet
base.
E. Refer to the "Handle Switch
Troubleshooting Table."
Refer to the "Sensor
F.
Troubleshooting Table."
G. Refer to the "Cleaning the
Screens" section.
A. Confirm the supply stops are
fully open.
B. Rotate the handle to the full
open position.
16