Kohler K-72218 Guía De Instalación Y Cuidado página 18

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting (cont.)
Solenoid Troubleshooting Table
Symptoms
Probable Causes
B. Solenoid
valve is not
functioning.
Handle Switch Troubleshooting Table
Symptoms
Probable Causes
1. Handle
A. Valve
LED is lit
setscrew
when the
needs
handle is
adjustment.
closed.
2. Handle
A. Valve
does not
setscrew
return to
needs
the upright
adjustment.
position.
3. Water does
A. Valve
not fully
setscrew
shut off.
needs
adjustment.
4. Handle
A. Loose handle
LED does
switch wire
not
connection.
illuminate
B. Circuit board
when the
is not
handle is
functioning
rotated
correctly.
open.
Sensor Troubleshooting Table
Symptoms
Probable Causes
1. Intermittent
A. Debris on the
sensor
sensor lens.
operation.
B. Sensor is
detecting
steam.
2. Handle
A. Loose sensor
LED is lit,
wire
but green
connection.
sensor
LED is not.
1186051-2-D
Recommended Action
B. Replace the solenoid valve
assembly.
Recommended Action
A. Refer to the "Handle LED
Adjustment" section.
A. Refer to the "Handle LED
Adjustment" section.
A. Refer to the "Handle LED
Adjustment" section.
A. Check handle switch wire
connection to the circuit board.
B. Replace the cover assembly.
Recommended Action
A. Use mild soap and water to
gently remove debris from the
sensor lens.
B. Rotate the spout away from the
steam.
A. Check sensor wire connection
to the circuit board.
18
Kohler Co.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

K-72218-vs

Tabla de contenido