PROTEOR GERY Instrucciones De Uso página 5

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
2
0
Instructions for use for Prosthetists/Orthotists
0
9
Please read before using or working on the device
1. COMPONENTS INCLUDED
2. DESCRIPTION, PROPERTIES AND MECHANISM OF ACTION
A. Description
A prosthetic foot designed to allow older adult patients to perform their everyday
activities, consisting of:
A core and foot shell which cannot be disassembled
A malleolar clip
The hole in the lower face of the foot is used to identify the location of the gap
between the big toe and the other toes, so that a separation can be made if required
to allow sandal-type footwear to be worn.
To make the cut, use a band saw to saw through to the hole and open up the cut as required.
B. Properties
3. INTENDED USERS/INDICATIONS
This medical device is supplied to healthcare professionals (prosthetists/orthotists) who then instruct the patient in how to use it. The
prescription is drawn up by a doctor. The doctor works with a prosthetist/orthotist to assess whether the patient is suited to using the
device.
This device should be used on ONE PATIENT ONLY. It must not be reused on other patients.
CAUTION: the GERY foot is not suitable for bilateral use by double amputees
4. CLINICAL BENEFITS
The device provides optimal comfort for below-knee and above-knee amputees when they perform their everyday activities.
5. ACCESSORIES AND COMPATIBILITIES
The foot incorporates a male pyramid link that allows it to be used with female pyramid connectors (refer to our catalogue).
The heel height can be adjusted from 0 to 20 mm.
6. ASSEMBLY AND FITTING TO THE PATIENT
A. Assembly and Aligning
Assemble in the normal way, checking that the load line passes 5 to 15 mm in front of the axis of the pyramid and provides a stable
upright position for the patient.
GERY - 1A200-HD
Pass on § 3, 7, 8 and 9 of these instructions to the Patient
Designation
Foot shell
Malleolar clip
Weight (Size 25)
Side
Size
Malleolar clip
Maximum patient
weight
(Including carried load)
This device is exclusively intended to be used as orthopaedic equipment for a below-knee or above-knee
amputee whose activity level is low (1) to medium (2).
Maximum weight (including carried load): 150 kg
Designed to accommodate a heel height of 0 to 20 mm.
Ref.
Included/Sold separately
1A200-xx
Included
1D101
Included
395 g
Right or Left
22 to 25
1D101-2225
1D101-2629
150 kg
26 to 29
1A20099
2021-04
Saw here

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

1a200-hd

Tabla de contenido