OPEraTION
Cleaning, care and maintenance
5.
Cleaning, care and maintenance
f Never use abrasive or corrosive cleaning agents. A damp
cloth is sufficient for cleaning the appliance.
f Check the taps regularly. Limescale deposits at the tap out-
lets can be removed using commercially available descaling
agents.
f Have the electrical safety of the appliance regularly checked
by a qualified contractor.
f Regularly descale or replace the special aerator (see chapter
"Appliance description / Accessories").
8
| EIL Premium
6.
Troubleshooting
Problem
Cause
The appliance will not
No power at the appli-
start despite the DHW
ance.
valve being fully open.
The aerator in the tap is
scaled up or dirty.
The water supply has
been interrupted.
The required tempera-
The maximum tempera-
ture is not being reached.
ture set inside the appli-
ance is too low.
The appliance has
reached its output limit.
If you cannot remedy the fault, notify your qualified contractor.
To facilitate and speed up your request, provide the number from
the type plate (000000-0000-00000).
Model:
EIL . . .
E no.:
000000
F no.:
0000-00000
remedy
Check the fuse/MCB in
your fuse box/distribu-
tion board.
Clean and/or descale the
aerator or replace the
special aerator.
Vent the appliance and
the cold water inlet line
(see chapter "Settings").
Have your qualified con-
tractor adjust the maxi-
mum temperature.
Reduce the flow rate.