- GB -
− The unit may only be connected when the electrical data of the unit and the power supply coincide. The unit data is
to be found on the unit type plate or on the packaging, or in this manual.
− Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.
− Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use.
− Ensure that the power connection cable cross section is not smaller than that of the rubber sheath with the
identification H05RN-F. Extension cables must meet DIN VDE 0620.
− Protect the plug connections from moisture.
− Install the transformer at a minimum safety distance of 2 m from the water.
− Only plug the unit into a correctly fitted socket.
Safe operation
− Never operate the unit if either the electrical cables or the housing are defective!
− Do not carry or pull the unit by its electrical cable.
− Route all cables such that damage is excluded and nobody can trip over them.
− Never open the unit housing or its attendant components, unless this is explicitly required in the operating
instructions.
− Only use original spare parts and accessories for the unit.
− Never carry out technical modifications to the unit.
− Only have repairs carried out by customer service points authorised by OASE.
− Only operate the unit with the supplied transformer.
− Keep the socket and power plug dry.
− Never look directly into the light source of the unit.

Installation, connection and alignment

Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
− For use, install the transformer at a minimum safety distance of 2 m from the bank (A).
− Choose an installation place for the transformer that is splash-water protected. Also protect the transformer
against sun radiation (max. 40 °C).
Installation variants (B)
The unit can be installed floating or standing in the water.
− When used floating, the unit position is fixed by bracing cords fastened at the eyelets (1) at the bottom of the unit
− When used standing, place the unit horizontally in the water (3) on a firm ground (4); level with rocks, if necessary.
Please note that the unit has to be installed at an approx. 80 mm water depth. If placed too deep in the water, safe
hold is not guaranteed due to buoyance.
Note:
− Ensure that the water inlet at the unit underside is not impaired.
− The floating bodies can be removed for a safer stand of the unit.
Connection (C)
Connect the unit and the transformer using the two-pole plug (6). Fasten the plug using the union nut (7).
Alignment (D)
Adjust the individual movable nozzles to align the water jet (8).