EQS
Nominal cooling capacity
EER
Nominal cooling capacity EN 14511
EER EN 14511
SEER EN 14825
Sound pressure
Sound power
Sound power with FNR accessory
Screw/step compressor
Circuits
Fans
Fan nominal air flow
Heat exchanger
Heat exchanger nominal flow water side
Nominal pressure drops on the water side exchanger
Residual head P1
Residual head P2
Nominal thermal potential RC100
Nominal flow rate/pressure drop RC100
Nominal thermal potential DS
Nominal flow rate/pressure drop DS
R134a coolant load
Polyester oil charge
Electrical data
Absorbed power
Pump absorbed power (P1/DP1)/(P2/DP2)
Electrical power supply
Auxiliary power supply
Nominal current
Maximum current
Starting current
Starting current with SFS
Pump absorbed current (P1/P2)
Dimensions
Height
Width
Length
Heat exchanger inlet/outlet connections
RC100 inlet/outlet connections
DS inlet/outlet connections
Weight
EQS
(*)
Under the following conditions: condenser inlet air temperatu- re
35°C; chilled water temperature 7°C; temperature differential at
evaporator 5 K; fouling factor equal to 0.35x10-4 m2 K/W.
(***)
Average sound pressure level in dB(A) calculated to a 10 m di- stance
from the unit, in free field and directionality factor equal to Q=2
according to ISO 3744. The noise data refers to the units without
the electric pump
(****)
Sound power level in dB(A) on the basis of measurements
taken in accordance with UNI EN-ISO 9614 and Eurovent 8/1
Standards. The noise data refers to the units without the electric
pump
(Δ)
If the SFS accessory is used, the length of the unit is increased
by 100mm
(+)
See the RC100/DS Water connections section
The refrigerant charge values are indicative. Refer to the serial number plate
2805
2865
800
861
(*)
kW
3.04
2.94
797.5
857.9
(*) (°)
kW
3
2.9
(*) (°)
4.57
4.57
dB(A)
67.5
68
(*) (***)
100
101
(*) (****) dB(A)
94
95
(*) (****) dB(A)
2/ CONTINUOUS LINEAR ADJUSTMENT (25-100%)
n°
2
2
n°
12x1.8
12x1.8
n°xKw
234000
234000
m
3
/h
Type
137.5
148
(*)
m
/h
3
42
50
(*)
kPa
144
128
(*)
kPa
191
176
(*)
kPa
1035
1125
(±)
kW
178 / 26 193.5 / 26 207.9 / 29 221.7 / 29 238 / 28 249.3 / 28 282.7 / 35
(±)
m
/h/kPa
3
135
146
(±)
kW
11.6 / 19
12.6 / 19
(±)
m
3
/h/kPa
Kg
100
100
Kg
49
60
2805
2865
263
293
(*) (■)
kW
11/15
11/15
kW
V-ph-Hz
V-ph-Hz
442
492
( )
A
506
562
( )
A
(◊)
A
714
770
(■)
(◊)
1114
1170
(■)
A
20.5/26.8 20.5/26.8 20.5/26.8 20.5/26.8 20.5/26.8 20.5/26.8 20.5/26.8
A
2805
2865
2450
2450
mm
2260
2260
mm
(Δ)
7150
7150
mm
Ø
DN150 VIC DN150 VIC DN150 VIC DN150 VIC DN200 VIC DN200 VIC DN200 VIC
2xDN100
2xDN100
(+)
Ø
VIC
VIC
(+)
Ø
DN50 VIC
DN65 VIC
2805
2865
5280
5700
kg
(±)
Recovery unit heating capacity Conditions referring to the unit operating
with chilled water temperature 7°C, differential tem- perature due
to evaporation of 5 K, hot water temperature pro- duced equivalent
to 40/45°C (RC100) 50/60°C (DS)
( )
Absorbed current/absorbed power value without electric pump
(◊)
The peak current refers to the unit's most heavy duty operating
conditions. At the nominal working condition the starting cur-
rent is reduced by approximately 8% without SFS and by 6%
with SFS
(°)
Data calculated in accordance with EN 14511:2018 under no- minal
conditions
SEER
Seasonal energy efficiency: low temperature cooling (EU Regu-
lation 2016/2281)
N.D.
Not avaiable
204
EQS
2935
2995
21075
934
990
1076
3.03
2.97
3.11
930.2
985.7
1072.1
2.98
2.92
3.06
4.58
4.55
4.58
68
68
69
101
101
102
95
95
96
2
2
2
14x1.8
14x1.8
16x1.8
273000
273000
312000
Shell and tube
160.6
170.2
185
58
64
52
112
101
106
161
150
156
1209
1289
1384
155
168
183
13.3 / 23
14.4 / 23 15.7 / 24 16.3 / 20
106
106
124
60
60
60
2935
2995
21075
310
333
346
11/15
11/15
11/15
400-3-50
230-1-50
521
560
581
618
666
713
899
947
1019
1425
1473
1586
2935
2995
21075
2450
2450
2450
2260
2260
2260
8250
8250
9350
2xDN100
2xDN100
2xDN100
VIC
VIC
VIC
DN65 VIC
DN65 VIC
DN65 VIC DN 65 VIC DN65 VIC
2935
2995
21075
6070
6130
6620
21115
21275
1115
1277
2.98
3.11
1110.7
1271
2.94
3.06
4.57
4.65
69
69
102
102
96
96
2
2
16x1.8
18x1.8
312000
351000
191.7
219.6
56
72
96
63
147
116
1450
1644
189
213
18.3 / 25
124
130
60
60
21115
21275
374
410
11/15
11/15
628
689
752
760
1058
1066
1625
1633
21115
21275
2450
2450
2260
2260
9350
10450
2xDN100
2xDN100
VIC
VIC
21115
21275
6640
7000