II.2
ACCESSORIES
IMPORTANT!
Only Use original spare parts and accessories.
HITECSA shall not be held liable for damage caused
by tampering with or work carried out by
unauthorised personnel or malfunctions caused by
the use of non-original spare parts or accessories.
II.2.1
Factory Fitted Accessories
P1 – Installation with pump.
P2 - Installation with increased static pressure pump
DP1 – Installation with double pump, including an automatically
activated pump in stand-by.
DP2 – Installation with increased static pressure double pump, including
an automatically activated pump in stand-by.
FW - Electromechanical flow switch (as an alternative to the differential
pressure switch mounted as standard)
BCI – Soundproof compressor box
ADVANCE
BCI ACCESSORIES
EQS
RR - Unit with compressor suction cut-off valves (the discharge valve is
as per standard)
SLO - Oil level sensor (this accessory is recommended in installations
where visual control of the compressor sight-glass is difficult or where a
more in-depth monitoring is required)
DS - Desuperheater
RC100 - Heat recovery unit with 100% recovery. Refer to the specific
section for more details
FI15 - Modulating condensation control with fans with EC motor
(Brushless) for continuous operation as a chiller up to -15°C outdoor air
temperature
FIAP - Condensing control with over-pressured fans with EC motor
(Brushless) and available static head according to the following table:
Available static head
Single fan absorption
Average increase in noise of the unit
SFS – Soft Starter compressors.
CR - Power factor correction capacitors
IM - Unit with circuit breaker switches protecting compressors and fans
FDL - Forced Download Compressors Compressor status management
(forcing them to OFF or limiting them) to limit the power and absorbed
current
FNR – Forced Noise Reduction. Forced reduction of noise (digital input
or time band management) - See specific section for more information
GM - Refrigerant circuit high and low pressure gauges.
RQE - Electrical panel resistance (recommended for low outdoor air
temperatures)
RA - Evaporator antifreeze resistor to prevent the risk of ice formation
inside the exchanger when the machine is switched off (as long as the
unit is not disconnected from the power supply).
RDR - Antifreeze electric heater for desuperheater / heat recovery (DS
or RC100), to prevent the risk of ice formation inside the recovery
exchanger when the machine is switched off (as long is the unit is not
disconnected from the power supply).
RAE1 - Electric pump antifreeze heater (available for P1-P2 set ups);
used to prevent the risk of the water inside the pump from freezing
when the machine is switched off (provided the unit is not disconnected
from the power supply)
RAE2 - Antifreeze heater for double electric pumps (available for DP1-
DP2 set ups); used to prevent the risk of the water inside the pump from
freezing when the machine is switched off (provided the unit is not
disconnected from the power supply)
LKD - Refrigerant leak detector
DSP – Double set-point via digital consensus (incompatible with the CS
accessory).
BCI-option
Unit with a Ø800mm fan
Up to 150 Pa
Max 2.8 kW
2 dBA
CS - Scrolling set point via analogue signal 4-20 mA (incompatible with
the DSP accessory).
CMT - Control of minimum and maximum values of power voltage.
BT – Low temperature of water produced.
SS - RS485 interface for serial communication with other devices
(proprietary protocol; Modbus RTU protocol)
EEM – Energy Meter. Measure and display values of the electrical units
FTT10 - LON interface for serial communication with other devices
(LON protocol).
RPB - Coil protection networks with accident prevention function (to be
used as an alternative to the FMB accessory).
RPE - Lower compartment protection mesh
PTL - Side damping panels within an aesthetic, accident prevention and
anti-intrusion function (to use as an alternative to the RPB accessory
and only for chiller models).
DVS – High pressure double safety valve with exchanger tap (the valve
is only on the outlet branch. In the case of options, such as DS/RC100
recovery units or tube and shell heat exchangers, please contact the
Pre-Sales department for a quotation and feasibility of the additional
double valves).
IMB - Protective packaging
SAM – Spring anti-vibration mountings (supplied not installed).
MCHXE - AL/AL micro-channel coil with E-coating treatment
VPF_R+INVERTER P1/DP1/ASP1/ASDP1 - Variable Primary Flow.
The accessory includes management via inverter of the primary side
pump(s) supplied as optional P1/DP1, ASP1/ASDP1 (check that the
total water content is at least 5lt/kW), the temperature probes and the
management software of the chiller
VPF_R+INVERTER
P2/DP2/ASP2/ASDP2 - Variable Primary Flow. The accessory
includes management via inverter of the primary side pump(s)
supplied as optional P2/DP2, ASP2/ASDP2 (check that the total water
content is at least 5lt/kW), the temperature probes and the
management software of the chiller
INV_P1/DP1/ASP1/ASDP1 - P1/DP1/ASP1/ASDP1 pump adjustment
(which must be chosen as optional) via inverter for
calibration/commissioning of the system. At the end of calibration, the
unit must work at a constant flow rate.
INV_P2/DP2/ASP2/ASDP2 - P2/DP2/ASP2/ASDP2 pump adjustment
(which must be chosen as optional) via inverter for
calibration/commissioning of the system. At the end of calibration, the
unit must work at a constant flow rate.
II.2.2
Accessories supplied separately
KTRD - Thermostat with display
KTR – Remote keypad for control at a distance with LCD display and
same functions as the machine. Connection must be made with a 6-
wire telephone cable (maximum distance 50 m) or with
KRJ1220/KRJ1230 accessories. For greater distances up to 200 m, use
an AWG 20/22 shielded cable (4 wires+shield, not supplied) and the
KR200 accessory.
KRJ1220 – Connection cable for KTR (length 20m)
KRJ1230 – Connection cable for KTR (length 30m)
KR200 - KTR remote control Kit (distance between 50 and 200m)
KRS485 - Interface RS485 for serial dialogue with other devices
(proprietary protocol, Modbus RTU protocol)
KFTT10 - LON interface for serial communication with other devices
(LON protocol)
KBE – Ethernet interface for serial communication with other devices
(BACnet IP protocol)
KBM – RS485 interface for serial communication with other devices
(BACnet MS/TP protocol)
KUSB – RS485/USB serial converter (USB cable supplied)
Description and fitting instructions are supplied with each
accessory.
II.2.3
Guide to choosing the MCXHE accessory
The aluminium alloys used in MCHX are the best available. However,
even the best aluminium alloy needs further protection against
corrosion in corrosive environment.
The purpose of this document is to guide our customers in choosing the
MXCHE accessory. To do this, attention is required to the classification
of different environments in relation to pollution and corrosion of the
metal.
55