Notice to installing contractor: Instructions must remain with installation.
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
Register your
Zoeller Pump Company
Product on our website:
http://reg.zoellerpumps.com/
Many Zoeller products contain
registered trademarks for
design and/or the color green:
U.S. #4,849,524 / #5,024,907
* Effluent systems should specify that pumps should not handle solids exceeding 3/4" (19 mm) in order to prevent large solids from entering leeching fields, mound
systems, etc. (70 Series have 3/8" (9 mm) solids capability. 50, 140/4140, 371 and 372 Series have 1/2" (13 mm), 130 Series has 5/8" (16 mm), 145/4145, 160/4160, 180/4180
and 373 models have 3/4" [19 mm].) Where code permits, sewage pumps can be used for effluent systems. Non-automatic pumps with external-level controls are
recommended for septic tank effluent applications.
PREINSTALLATION CHECKLIST - ALL INSTALLATIONS
1. Inspect all materials. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using. DO NOT remove the test plugs
from the pump.
2. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should be retained for future
reference.
1. To reduce the risk of electrical shock, a properly grounded receptacle or
control box must be installed in accordance with the governing codes. Never
remove ground pin from plug.
2. Make certain that the ground fault interrupter protected receptacle or control
box is within the reach of the pump's power supply cord. DO NOT USE AN
EXTENSION CORD. Extension cords that are too long or too light do not deliver
sufficient voltage to the pump motor, and they could present a safety hazard
if the insulation were to become damaged or the connection end were to fall
into a damp or wet area.
3. Make sure the pump's electrical supply circuit is equipped with fuses or circuit
breakers of proper capacity. A separate branch circuit is recommended, sized
according to the local electrical codes for the current shown on the pump
name plate.
4. Testing for ground. As a safety measure, each electrical outlet should be checked
for ground using a circuit analyzer which will indicate if the power, neutral and
ground wires are correctly connected to your outlet. If they are not, call a quali-
fied licensed electrician.
5. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER
SOURCE BEFORE HANDLING. If pump is wired direct, de-energize the circuit
at the control box. Wear insulated protective shoes and do not stand in water.
Pumps equipped with a 3-prong ground plug are designed to help protect
against electrical shock. DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE
THE GROUND PIN.
6. Installation and servicing of the pump, electrical circuits and hardware should
only be performed by a qualified, licensed electrician.
7. Risk of electrical shock. Do not remove power supply cord and strain relief
or connect conduit directly to the pump. If the supply cable is damaged, it
must be replaced by the Manufacturer or an Authorized Service and Warranty
Center to avoid a hazard.
8. Pump contains oil which becomes pressurized and hot when operating. Allow
2-1/2 hours after disconnecting before attempting service.
9. Pump is not intended for potable water due to possible contamination by oil
contained in the pump.
10. Risk of electrical shock. These pumps have not been investigated for use in
swimming pools and marine areas.
11. Prop65 Warning for California residents: Cancer and Reproductive Harm-
www.P65Warnings.ca.gov.
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
TEL: (502) 778-2731 • 1 (800) 928-PUMP • FAX: (502) 774-3624
INSTALLATION INSTRUCTIONS
RECOMMENDED MODELS
EFFLUENT*/SUMP/DEWATERING
49, 72, 73, 75, 76 Series
SEE BELOW FOR
LIST OF WARNINGS
© Copyright 2020 Zoeller
SEWAGE
211, 212 Series
CAUTION
1. Check to be sure your power source is capable of handling the voltage
requirements of the motor, as indicated on the pump name plate.
2. The installation of variable level float switches is the responsibility of the
installing party, and care should be taken that the tethered float switch will
not hang up on the pump apparatus or pit peculiarities and is secured so that
the pump will shut off. It is recommended to use rigid pipe and fittings and
the pit be 18" (46 cm) or larger in diameter.
3. Vent hole. It is necessary that all submersible sump, effluent, and sewage
pumps capable of handling various sizes of solid waste be of the bottom intake
design to reduce clogging and seal failures. If a check valve is incorporated
in the installation, a 3/16" (5 mm)vent hole must be drilled in the discharge pipe
below the check valve and pit cover to purge the unit of trapped air. Vent
hole should be checked periodically for clogging. The vent hole on a High
Head application may cause too much turbulence. If you choose not to drill a
vent hole, be sure the pump case and impeller is covered with liquid before
connecting the pipe to the check valve. NOTE: THE HOLE MUST BE BELOW
THE BASIN COVER AND CLEANED PERIODICALLY. Water stream will be visible
when pump is operating.
4. Pump should be checked frequently for debris and/or build up which may
interfere with the float "on" or "off" position. Repair and service should be
performed by an Authorized Service and Warranty Center.
5. Maximum operating temperature for standard model pumps must not exceed
130 °F (54 °C). Maximum operating temperatures for 70 series and model
211 must not exceed 110 °F (43 °C). Maximum operating temperatures
for 73, 75, 212 series must not exceed 104 °F (40 °C).
6. Do not operate a pump in an application where the Total Dynamic Head is
less than the minimum Total Dynamic Head listed on the Pump Performance
Curves.
7. For health reasons, do not unplug, turn off, or disable pump and use pump tank
system as a way to fill up a sink or laundry tray, etc.
8. Pumps must be installed in accordance with the National Electrical Code
and all applicable local codes and ordinances. Pumps are not to be installed
in locations classified as hazardous in accordance with National Electric Code,
ANSI, NFPA 70.
NOTE: Pumps with the "UL" mark and pumps with the "US" mark are tested to UL
standard UL778. CSA certified pumps are certified to CSA standard C22.2 No. 108.
REFER TO WARRANTY ON PAGE 2.
Co. All rights reserved.
®
1
FM3174
Supersedes
Visit our website:
zoellerpumps.com
DATE INSTALLED:
MODEL NUMBER:
NOTICE: VENT HOLE FOR
CHECK VALVE
SEE #3 IN CAUTION SECTION
BELOW AND #4 ON PAGE 3
SEE BELOW FOR
LIST OF CAUTIONS
1120
0220

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Zoeller 49 Serie

  • Página 1 INSTALLATION INSTRUCTIONS RECOMMENDED MODELS MODEL NUMBER: NOTICE: VENT HOLE FOR EFFLUENT*/SUMP/DEWATERING SEWAGE Many Zoeller products contain CHECK VALVE registered trademarks for SEE #3 IN CAUTION SECTION 49, 72, 73, 75, 76 Series 211, 212 Series design and/or the color green: BELOW AND #4 ON PAGE 3 U.S.
  • Página 2 If the above checklist does not reveal the problem, consult the Product Support Department. Do not attempt to service or otherwise disassemble pump. Service must be peformed by a Zoeller Authorized Service and Warranty Center. Visit www.zoeller.com for a complete list of service centers.
  • Página 3 1. Electrical wiring and protection must be in accordance with governing before starting pump. electrical codes. 2. Install proper Zoeller Unicheck (combination union and check valve), 9. Basin must be clean and free of debris after installation. preferably just above the basin to allow easy removal of the pump 10.
  • Página 4: Important Notice

    IMPORTANT NOTICE: Some insurance policies, both commercial and residential, extend coverage for damages incurred by product failure. You will need to have possession of the product to support your claim in most cases. Zoeller Pump Co. will exchange the unit or refund the original purchase price once the claim is settled with the insurer in the case where you need to retain possession of the product to support a damage claim you submit to your insurance company.
  • Página 5: Modelos Recomendados

    7. Riesgo de descarga eléctrica. No quite el cable de alimentación eléctrica ni por Zoeller Pump Company. el dispositivo de alivio de tensión y no conecte un conductor directamente a la 5.
  • Página 6: Garantía Limitada

    Si la lista de verificación arriba mencionada no revela el problema, consulte con el departamento de Product Support. No intente proporcionar algún servicio o desarmar la bomba. Los centros de servicio autorizadas por Zoeller deberán proporcionar dicho servicio. © Copyright 2020 Zoeller Co.
  • Página 7: Instalación Recomendada Para Todas Las Aplicaciones

    DE LA TAPA DEL ESTANQUE Y SE DEBE LIMPIARLO PERIÓDICAMENTE. 14. Instale el soporte para bomba Zoeller (Modelo 10-2421) debajo de la (Para unidades de carga elevada, ver el número 3 de la lista de bomba para proporcionar un sumidero de decantación (sólo para efluente “Precauciones”...
  • Página 8: Instalación De Los Modelos Wd Y Wh

    AVISO IMPORTANTE: Ciertas pólizas de seguro, tanto comerciales como residenciales, extienden la cobertura a los daños causados por la falla del producto. En la mayoría de los casos, usted deberá conservar el producto para respaldar su reclamo. Zoeller Pump Co. reemplazará la unidad o reembolsará...
  • Página 9 / arrêt. Les réparations ne 6. L’installation et la vérification de l'équipement électrique doivent être faites par un doivent être faites que par un centre de réparation agréé par Zoeller Pump Company. électricien qualifié.
  • Página 10: Garantie Limitée

    Ne pas trop serrer les raccords ni les vis. Si les vérifications ci-dessus ne résolvent le problème, consulter l’usine. Ne pas essayer de réparer ou de démonter la pompe. Toutes les réparations doivent être faites par un centre de réparation agréé par Zoeller. © Copyright 2020 Zoeller Co.
  • Página 11 Il est possible de fabriquer les supports de flotteur en utilisant des tuyaux et des raccords standard pour faciliter la dépose en cas de réparation. Les supports de flottes sont disponible chez Zoeller tel que décrit au feuillet FM0526 ou peuvent être fabriqué avec de la tuyauterie et des raccords standard.
  • Página 12: Instructions De Branchement Monophasé

    REMARQUE IMPORTANTE – Certaines polices d’assurance commerciales et résidentielles couvrent les dommages résultant d’une défaillance du produit. Dans la plupart des cas, vous devez être en possession du produit pour déposer une réclamation. Zoeller Pump Co. s’engage à remplacer l’appareil ou à...